LARGE EJ SERIES FOUNTAIN MANUAL

1

MOVING WATER FORWARD, SINCE 1968

Operation & 
Maintenance 

Manual

Document number 884157
Document version 2022.1.0

EJ SERIES 

FOUNTAIN

5.3EHJ

800 Deere Rd. Prescott, WI 54021  |  [email protected]  |  kascomarine.com

Summary of Contents for 5.3EHJ

Page 1: ...UNTAIN MANUAL 1 MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884157 Document version 2022 1 0 EJ SERIES FOUNTAIN 5 3EHJ 800 Deere Rd Prescott WI 54021 sales kascomarine com kascomarine com ...

Page 2: ...ncluded 5 Installation Instructions 9 Maintenance Recommendations 11 Troubleshooting Tips 12 Warranty 13 Other Repairs 14 Repair Contact Form 15 OVERVIEW Model HP Voltage Phase Hz Amperage Locked Rotor Amps Suggested Pond Size m Min Depth of Operation 5 3EHJF 5 380 3 50 7 7 27 10 000 71cm UNIT SPECIFICATIONS Wire size for all cord lenths is 2 5mm ...

Page 3: ...nd national codes Stay clear of all moving parts NEVER run the unit out of water This will damage the equipment and pose a danger to the operator Use extreme caution around water especially cold water NEVER lift or drag the unit by the power cord Always use the ropes or mount to remove it from the water Do not use waders in deep water or in areas with drop offs drastic slopes or soft bottom materi...

Page 4: ...on F Nozzle O ring Large J 1 841217 G Large JF unit assembly 1 See Table below H Bottom screen large aerator 1 990162 I Bottom screen clip large aerator 3 223240 J 3 8 16 x 1 2 serrated hex head screw 3 820092 K 7 16 9 16 wrench tool 1 284139 L 1 4 mesh screen not pictured 1 990175 M 3 4 mesh screen not pictured 1 990170 N Rope 50ft not pictured 1 990170 O Cable tie not pictured 8 415038 P Dielect...

Page 5: ...Outlet Balsam 841273 HP Height Width 5 4 7m 9 4m Spruce 841242 HP Height Width 5 7 9m 2 7m HP Height Width 5 5 8m 3m Birch 841222 Redwood 841250 HP Height Width 5 8 1m 1 8m 841242 Spruce 841250 The outlet nozzle 841222 comes installed Add the parts listed below for Linden and Balsam patterns remove it before installing Birch Spruce or Redwood nozzles ...

Page 6: ...com or your local distributor for order information Madrone 841330 Magnolia 841325 Palm 841320 Mahogany 841345 Mighty Oak 841335 841250 841250 841250 841250 841250 HP Height Width 5 7m 18 9m HP Height Width 5 6 2m 22 6m HP Height Width 5 5 1m 10 4m HP Height Width 5 6 9m 18 9m HP Height Width 5 6 9m 18 3m ...

Page 7: ...LARGE EJ SERIES FOUNTAIN MANUAL 6 ASSEMBLY INSTRUCTIONS Dedicated power cord channel D G A B C 1 2 3 Repeat I J 4 ...

Page 8: ...BLY INSTRUCTIONS CONT 5 6 7 8 Use cable ties to secure close mesh screen and then to secure it to the metal bottom screen H Dedicated power cord channel 9 Tighten all 3 screws to secure float screen Vertical bar in between clip flanges 10 11 ...

Page 9: ...LARGE EJ SERIES FOUNTAIN MANUAL 8 NOZZLE INSTALLATION INSTRUCTIONS Twist until snug For Linden Balsam Nozzles OUTLET 6 nozzle installed Balsam Linden F E 1 2 3 Do not over tighten 1 2 ...

Page 10: ... rope Secondary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least 3 feet from the float for every foot of water depth Mooring lines are too short or loose between unit and anchors ...

Page 11: ...to specified torque setting prior to energizing the panel 2 Verify the electrical service voltage and phase matches the control panel and fountain nameplate ratings 3 Verify all switches circuit breakers and motor starters are in the OFF position 4 Connect electrical service to the control panel 5 Connect the fountain power cord to the panel as shown in the electrical schematic 6 Adjust motor over...

Page 12: ...is inspect and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is still wet If you use a power washer avoid hitting the mechanical seal area directly Unit Storage Store the equipment with the cage down if it is going to be out of the water for long perio...

Page 13: ...s and will not start Typically indicates a motor capacitor problem single phase motor a motor controller problem 3 phase or debris preventing the unit from starting Turn the unit off and disconnect from power source to prevent motor damage Remove the equipment from the water and inspect for debris or damage Remove the debris and clean the equipment If there is no debris in the unit and it will not...

Page 14: ... Once the warranty coverage has been established the unit may be sent to any Kasco authorized repair center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information or a repair form or call to locate your nearest authorized repair center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or yo...

Page 15: ...st for repairs after we have evaluated the unit but before we perform the work We will repair the unit only if repair costs are under a dollar amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will ...

Page 16: ...cian Was this unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is ...