SMALL EJ SERIES FOUNTAIN MANUAL
2
UNIT SPECIFICATIONS
SAFETY FIRST
OVERVIEW
Model
HP
Voltage / Phase / Hz Amperage
Locked Rotor
Amps
Suggested Pond
Size (m²)
Min� Depth
of Operation
2400EJF
1/2
230 / 1 / 50
2.2
5.3
1,000
38cm
3400EJF
3/4
230 / 1 / 50
3.5
9
1,350
45cm
Cord Length
10m
30m
60m
90m
2400EJF
1.5mm
²
1.5mm
²
2.5mm
²
2.5mm
²
3400EJF
1.5mm
²
1.5mm
²
2.5mm
²
2.5mm
²
WIRE SIZE
Moving Machinery
WARNINGS:
Shock Hazard
• NEVER enter the water with the electrical equipment connected and/or in operation.
• All electrical equipment must be Ground fault/leakage current protected. Use of a Ground fault
protective device (GFI, RCD, RCBB, or RCBO type device) is required as directed by local and national
codes.
• Stay clear of all moving parts.
• NEVER run the unit out of water. This will damage the equipment and pose a danger to the operator.
• Use extreme caution around water, especially cold water.
• NEVER lift or drag the unit by the power cord. Always use the ropes or mount to remove it from the
water.
•
Do not use waders in deep water or in areas with drop-offs, drastic slopes, or soft bottom material.
• Do not use boats that tip easily for unit installation (such as canoes).
• Follow all boating safety rules and regulations, including wearing a Personal Flotation Device.
• The unit is supplied with an internal grounding conductor. To reduce the risk of electrical shock, be
certain that the unit is plugged in/connected to a circuit with ground fault protection.
•
Means for disconnection must be incorporated in the fixed wiring, in accordance with local and national
wiring rules.
•
Consult a qualified electrician for electrical installation.
Back to Contents