The following is a list of potentially occurring problems (P) and the possible causes.
15.1
Fresh water system
(P) N
O WATER COMES OUT OF THE TAPS
.
Leave the tap in the bathroom and kitchen open for a few seconds to allow air to escape, which may have
become trapped in the water lines.
→
The fresh water tank is empty.
→
The fresh water pump is not switched on. (The symbol on the control panel is off.)
→
The filter of the fresh water pump is clogged.
→
The drain valves are open.
→
The boiler is empty.
→
The fuse for the fresh water pump (F7) has blown. (The cause has to be determined.*)
(P) T
HE WATER DOES NOT DRAIN FROM THE KITCHEN SINK
,
WASH BASIN OR SHOWER
.
→
The waste water tank is full.
→
The trap is blocked.
(P) W
ATER RUNS FROM UNDERNEATH THE VEHICLE
.
→
The fresh water tank is too full. Wait one minute until the excess water has drained.
→
The drain valve of the fresh water tank is open.
→
The waste water tank is full.
→
The drain valve of the waste water tank is open.
→
The drain valve of the boiler is open.
15.2
Electrical system
(P) O
NE OR SEVERAL ELECTRICAL APPLIANCES ARE NOT WORKING
.
→
The appliances are not in the “ON” position.
→
Circuit breaker B1 or B2 interrupts the current flow and has to be deactivated.
→
The power supply on the control panel is not activated.
→
The living room battery B2 is discharged. (See item 7.12 “Charging the living room battery B2”.)
→
The 230 V power supply is not established. (See item 7.4 “Establishing the 230 V power supply”.)
→
The RCD was triggered. (The cause has to be determined.*)
→
The fuse for the corresponding appliance has blown. (The cause has to be determined.*)
(P) T
HE INTERIOR LIGHTING IS NOT WORKING
.
→
The power supply on the control panel is not activated. (The “interior lighting” symbol on the control
panel does not light up.)
→
The light unit is switched off or defective.*
→
The fuse for the interior lighting (F5 or F6) has blown. (The cause has to be determined.*)
(P) T
HE EXTERIOR LIGHTING IS NOT WORKING
.
→
The power supply on the control panel is not activated. (The “exterior lighting” symbol on the
control panel does not light up.)
→
The light unit is defective.*
→
The fuse for the exterior lighting (F8) has blown. (The cause has to be determined.*)
(P) T
HE
230
V
SOCKET IS NOT WORKING
.
→
The 230 V power supply is not established. (See item 7.4 “Establishing the 230 V power supply”.)
→
The RCD was triggered. (The cause has to be determined.*)
Summary of Contents for DEXTER 600
Page 1: ...DEXTER 600 BEDIENUNGSANLEITUNG OPERATING MANUAL...
Page 3: ...DE 3 1 Allgemeines...
Page 10: ...DE 11 2 Verantwortung des Halters...
Page 15: ...DE 17 3 Sicherheit und Brandschutz...
Page 18: ...DE 21 4 Bef rderung von Personen...
Page 21: ...DE 25 5 Frischwasser anlage...
Page 30: ...DE 35 6 Gasanlage...
Page 35: ...DE 41 7 Elektrische Anlage...
Page 44: ...DE 51 8 Heizung...
Page 49: ...DE 57 9 WC Anlage...
Page 56: ...DE 65 10 K che...
Page 62: ...DE 73 11 Fenster und Dachhauben...
Page 71: ...DE 83 12 Wohnen...
Page 82: ...DE 95 13 Stilllegung ber den Winter...
Page 85: ...DE 99 14 Reinigung und Pflege...
Page 89: ...DE 105 15 St rungssuche...
Page 94: ...DE 111 16 Wartung und Wartungsintervalle...
Page 99: ...EN 3 1 General information...
Page 106: ...EN 11 2 Owner s responsibility...
Page 111: ...EN 17 3 Safety and fire protection...
Page 114: ...EN 21 4 Transporting passengers...
Page 117: ...EN 25 5 Fresh water system...
Page 126: ...EN 35 6 Gas system...
Page 131: ...EN 41 7 Electrical system...
Page 140: ...EN 51 8 Heating...
Page 145: ...EN 57 9 Toilet system...
Page 152: ...EN 65 10 Kitchen...
Page 158: ...EN 73 11 Windows and roof lights...
Page 167: ...EN 83 12 Living...
Page 178: ...EN 95 13 Laying up for winter...
Page 181: ...EN 99 14 Cleaning and maintenance...
Page 185: ...EN 105 15 Trouble shooting...
Page 190: ...EN 111 16 Maintenance and maintenance intervals...