EN 109
(P) T
HE
12
V
SOCKET IS NOT WORKING
.
→
The control panel is not activated.
→
The living room battery B2 is discharged. (See item 7.12 “Charging the living room battery B2”.)
→
The fuse for the 12 V socket (F9) has blown. (The cause has to be determined.*)
(P) T
HE ELECTRIC STEP IS NOT WORKING
.
→
The living room battery B2 is discharged. (See item 7.12 “Charging the living room battery B2”.)
→
The fuse for the electric step (F4) has blown. (The cause has to be determined.*)
→
The step is defective.*
15.3
Heating
(P) T
HE HEATING IS NOT WORKING
.
→
The “heating” circuit breaker interrupts the current flow and has to be deactivated.
→
The heating control panel (Truma CP plus) is not switched on.
→
The fuel tank of the vehicle is empty.
→
The 230 V power supply is not established. (See item 7.4 “Establishing the 230 V power supply”.)
→
The selected temperature is lower than the actual room temperature.
→
The intake opening for circulating air inside the vehicle is blocked.
→
The air intake/outlet element on the outside of the vehicle is blocked.
→
The window with the contactor on the window pane (if fitted) is not closed properly.
→
The fuse for the heating (slot 1) has blown. (The cause has to be determined.*)
15.4
Toilet
(P) T
HE TOILET SLIDE VALVE IS NOT WORKING
.
→
The cassette is full.
→
The cassette is not correctly engaged.
(P) T
HE TOILET CASSETTE CANNOT BE PULLED OUT OR PUSHED IN
.
→
The toilet slide valve is open or partially open.
(P) T
HE TOILET CANNOT BE FLUSHED
.
→
The fresh water tank is empty.
→
The fresh water pump is in no-load operation because there is air in the system.
→
The cassette is not correctly engaged.
→
The fuse for the toilet (F9) has blown. (The cause has to be determined.*)
15.5
Kitchen
(P) T
HE REFRIGERATOR IS NOT WORKING
.
→
The refrigerator is switched off.
→
The living room battery B2 is discharged. (See item 7.12 “Charging the living room battery B2”.)
→
The fuse for the refrigerator (slot 2) has blown. (The cause has to be determined.*)
(P) T
HE HOB IS NOT WORKING
.
→
The safety valve on the gas cylinder (gas cylinder compartment) is closed.
→
The gas cylinder is empty.
(P) H
IGH GAS CONSUMPTION
/
GAS ODOUR
→
The gas system has a leak.*
Summary of Contents for DEXTER 580 2021-2022
Page 1: ...DEXTER 580 625 BEDIENUNGSANLEITUNG OPERATING MANUAL...
Page 3: ...DE 3 1 Allgemeines...
Page 10: ...DE 11 2 Verantwortung des Halters...
Page 15: ...DE 17 3 Sicherheit und Brandschutz...
Page 18: ...DE 21 4 Bef rderung von Personen...
Page 21: ...DE 25 5 Frischwasser anlage...
Page 30: ...DE 35 6 Gasanlage...
Page 35: ...DE 41 7 Elektrische Anlage...
Page 44: ...DE 51 8 Heizung...
Page 49: ...DE 57 9 WC Anlage...
Page 56: ...DE 65 10 K che...
Page 61: ...DE 71 11 Fenster und Dachhauben...
Page 70: ...DE 81 12 Wohnen...
Page 85: ...DE 97 13 Stilllegung ber den Winter...
Page 88: ...DE 101 14 Reinigung und Pflege...
Page 92: ...DE 107 15 St rungssuche...
Page 97: ...DE 113 16 Wartung und Wartungsintervalle...
Page 102: ...EN 3 1 General information...
Page 109: ...EN 11 2 Owner s responsibility...
Page 114: ...EN 17 3 Safety and fire protection...
Page 117: ...EN 21 4 Transporting passengers...
Page 120: ...EN 25 5 Fresh water system...
Page 129: ...EN 35 6 Gas system...
Page 134: ...EN 41 7 Electrical system...
Page 143: ...EN 51 8 Heating...
Page 148: ...EN 57 9 Toilet system...
Page 155: ...EN 65 10 Kitchen...
Page 160: ...EN 71 11 Windows and roof lights...
Page 169: ...EN 81 12 Living...
Page 184: ...EN 97 13 Laying up for winter...
Page 187: ...EN 101 14 Cleaning and maintenance...
Page 191: ...EN 107 15 Trouble shooting...
Page 196: ...EN 113 16 Maintenance and maintenance intervals...