Maintenance plan
Fault
Cause
Rectification
The device shows "Ready for use" but
does not dispense water. All buttons
are illuminated.
The water supply is interrupted.
1. Ensure a correct water supply.
2. Check the shut-off devices.
3. If the fault persists, contact the service department.
The device is not working. The but-
tons do not light up.
The power supply is faulty.
Check the power supply.
The fuse is defective.
Remove the cover of the fuse next to the device switch, replace the
fuse. If the fuse blows again, switch off the device, contact the service
department.
The dispensed water is not cooled,
even though the "Chilled water" but-
ton was pressed
The cooling module has not reached its nominal tem-
perature.
1. Wait 20 to 40 minutes and check it again.
If the cooling function exhibits permanent failure:
2. Switch off the device.
3. Contact the service department.
The carbonated water and cold water
buttons light up alternately and a sig-
nal tone can be heard.
Temperature regulation fault.
Contact the service department.
The carbonated water button no
longer lights up after 60 seconds and
the dispensing of carbonated water is
blocked.
Refilling of the carbonator tank failed.
1. Switch off the device.
2. Check the water supply inlet.
3. Check the gas pressure.
4. Switch the device off and back on again.
5. If the fault persists, contact the service department.
Internal pump starts when dispensing
"CO
2
chilled water" with different de-
lays.
This is a normal function, not an error.
No fix necessary
Internal pump starts up briefly at reg-
ular intervals
This is a normal function for the function of the carbon-
ator tank.
No fix necessary
No carbonation in the water.
CO
2
gas pressure too low.
Correct the CO
2
gas pressure.
CO
2
bottle or CO
2
cylinder empty.
1. Replace the CO
2
bottle or the CO
2
cylinder.
2. If the fault persists, contact the service department.
Too little carbonation in the water
The cold water tank has not reached its nominal tem-
perature.
Check the carbonation in the water again after waiting 20 minutes.
The filter is dirty and reduces the necessary water flow. 1. Check the flow of the filter and replace the filter if necessary.
2. If the fault persists, contact the service department.
CO
2
bottle or CO
2
cylinder almost empty.
Replace the CO
2
bottle or the CO
2
cylinder.
Splashing delivery of carbonated wa-
ter for larger quantities
Refilling of the carbonator tank is impaired.
Check the flow of the filter and replace the filter if necessary.
The gas pressure setting is too high.
1. Correct the CO
2
gas pressure.
2. If the fault persists, contact the service department.
WPD 50
Ws
Device performance data
Working voltage of the battery
V
220-240
Power frequency
Hz
50
Power protection (slow-blowing)
A
6
Max. power input
W
200
Water supply pressure
MPa
(bar)
0,15 -
0,6
(1,5-6)
Water supply temperature
°C
5-30
Pressure adjustment range for
CO
2
MPa
(bar)
0,38...
0,42
(3,8...
4,2)
Ambient temperature
°C
5 - 32
Water dispenser (depending on supply pressure
and filter status)
Chilled water
l/h
120
CO
2
Carbonated water
l/h
80
Min. temperature of chilled water
°C
6
Dimensions and weights
Width
mm
300
Depth
mm
440
Height
mm
395
Weight
kg
19
WPD 50
Ws
Time & date
Performed
Daily
Remove and clean the drip tray.
After an overnight device standstill, dispense 0.5 l of each type of water and dispose of it.
Weekly, more often if neces-
sary
Clean the outside of the device, clean the drip tray with hot water or in a dishwasher.
Do not use cleaning agents containing alcohol, acidic components or scouring agents for cleaning plastic surfaces.
Half-yearly
If the water quality is bad, replace the Hy-Pure-Plus filter.
Perform chemical cleaning, see chapter
.
Annually
Replace Hy-Pure-Plus filter.
The decisive factor for the filter change interval is the amount of water dispensed and the water quality of the inlet water.