10
English
Check setting at the spray lance.
Check water supply for adequate delivery rate.
Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.
Remove air from appliance before operation.
Switch on the appliance without connection the HP
hose (max. 2 minutes) and run it until the water dis-
charging from the HP outlet is free of bubbles.
Switch off appliance and reconnect HP hose.
Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Dropwise leakage of the device is normal for tech-
nical reasons. If the leakage increases contact the
authorized customer service.
Turn the 3-in-1 multi jet spray lance to detergent
nozzle "MIX".
Check whether the Plug 'n' Clean detergent bottle
is placed into the detergent connection facing
down.
Check / replace the batteries
Decrease the distance between high-pressure gun
and high-pressure cleaner.
Couple it to the high-pressure cleaner again.
Switch off the device and pull the
mains plug out of the socket.
After 20 seconds, insert the power cord
back into the socket and switch the de-
vice on.
If the malfunction occurs repeatedly, have
the device checked by the customer ser-
vice.
If the pressure regulation on the high-pressure gun is
defective (electronic defect, battery empty, etc.), the
high-pressure cleaner continues operating at the level
that was last set.
To activate emergency operation at the maximum level:
Switch off the device and pull the mains plug out of
the socket.
Insert the power cord back into the socket and
switch the device on.
The warranty terms published by the relevant sales
company are applicable in each country. We will repair
potential failures of your appliance within the warranty
period free of charge, provided that such failure is
caused by faulty material or defects in manufacturing. In
the event of a warranty claim please contact your dealer
or the nearest authorized Customer Service center.
Please submit the proof of purchase.
Addresses can be found under:
www.kaercher.com/dealersearch
Pressure does not build up in the appliance
Strong pressure fluctuations
Appliance is leaking
No detergent infeed
No pressure indicator on the trigger gun
Error messages
Emergency operation
Warranty
Technical specifications
Electrical connection
Voltage
230-240
1~50
V
Hz
Connected load
2,1 kW
Type of protection
IPX5
Protective class
I
Mains fuse (slow-blow)
13 A
Water connection
Max. feed pressure
1,2 MPa
Max. feed temperature
40 °C
Min. feed volume
10 l/min
Max. Suction height
0,5 m
Performance data
Working pressure
12,5 MPa
Max. permissible pressure
14,5 MPa
Water flow rate
7,5 l/min
Max. flow rate
8,3 l/min
Detergent flow rate
0,3 l/min
Recoil force of the trigger gun
17 N
Remote module SRD
Frequency
868,7-
869,2 MHz
Transmission power ERP
0,53 mW
Dimensions and weights
Length
411 mm
Width
305 mm
Height
584 mm
Typical operating weight
15,8 kg
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
0,9
0,6
m/s
2
m/s
2
Sound pressure level L
pA
Uncertainty K
pA
78
3
dB(A)
dB(A)
Sound power level L
WA
+ Uncertainty
K
WA
94 dB(A)
Subject to technical changes.