You can rectify minor faults yourself with the help of the
following overview.
If in doubt, please consult the authorized customer ser-
vice.
DANGER
Risk of electric shock.
Prior to all work on the appliance, switch off the ap-
pliance and pull the power plug.
Pull on the lever of the trigger gun; the device will
switch on.
Check whether the voltage indicated on the type
plate corresponds to the voltage of the mains sup-
ply.
Check the mains connection cable for damages.
Check setting at the spray lance.
Check water supply for adequate delivery rate.
Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.
Appliance ventilation: Switch the appliance on with
the high-pressure hose detached and operate
(max. 2 minutes) until the water exits the high-pres-
sure connection without bubbles. Switch off appli-
ance and reconnect high-pressure hose.
Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Slight leakage from the appliance pump is normal.
If the leakage increases contact the authorized
customer service.
Use spray lance with pressure regulation (Vario
Power).
Turn the spray lance as far as it will go in the direc-
tion of "SOFT".
Clean the detergent suction hose filter.
Check the detergent suction hose for kinks.
The warranty terms published by the relevant sales
company are applicable in each country. We will repair
potential failures of your appliance within the warranty
period free of charge, provided that such failure is
caused by faulty material or defects in manufacturing. In
the event of a warranty claim please contact your dealer
or the nearest authorized Customer Service center.
Please submit the proof of purchase.
Addresses can be found under:
www.kaercher.com/dealersearch
Troubleshooting
Appliance is not running
Pressure does not build up in the appliance
Strong pressure fluctuations
Appliance is leaking
No detergent infeed
Warranty
Technical specifications
Electrical connection
Voltage
220-240
1~50-60
V
Hz
Power consumption
6 A
Protection class
IPX5
Protective class
II
Mains fuse (slow-blow)
10 A
Water connection
Max. feed pressure
1,2 MPa
Max. feed temperature
40 °C
Min. feed volume
8 I/min
Performance data
Working pressure
8 MPa
Max. permissible pressure
12 MPa
Water flow rate
5,5 I/min
Max. flow rate
6,3 I/min
Detergent flow rate
0,3 I/min
Recoil force of trigger gun
12 N
Dimensions and weights
Length
279 mm
Width
275 mm
Height
803 mm
Typical operating weight
7,0 kg
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
<2,5
0,3
m/s
2
m/s
2
Sound pressure level L
pA
Uncertainty K
pA
74
3
dB(A)
dB(A)
Sound power level L
WA
+ Uncertainty
K
WA
90 dB(A)
Subject to technical changes.
Summary of Contents for K 3
Page 1: ...cc 4 English 12 Register your product www kaercher com welcome 001 K 3 59786110 10 21...
Page 2: ...2...
Page 3: ...3...
Page 4: ...4 cc 60 IEC 60364 30 1 10 1 5 2 10 30 2 5 2 4 6 6 6 7 7 7 8 9 9 9 10 10 10 U 11...
Page 5: ...cc 5 30 0 C EN 12729 BA...
Page 6: ...6 cc FFP 2 REACH www kaercher com REACH K RCHER www kaercher com...
Page 8: ...8 cc 2 2 30 90 I ON I Vario Power SOFT 90 90 5 0 OFF 0 1 0 OFF 0...
Page 9: ...cc 9 1 2 Vario Power SOFT...
Page 19: ...19...