English
13
DANGER
Risk of electric shock.
Prior to all work on the appliance, switch off the ap-
pliance and pull the power plug.
Clean the sieve in the water connection regularly.
ATTENTION
The sieve must not be damaged.
Remove coupling from the water connection.
Pull the sieve out using flat pliers.
Clean the sieve under running water.
Reinsert the sieve into the water connection.
The appliance is maintenance free.
You can rectify minor faults yourself with the help of the
following overview.
If in doubt, please consult the authorized customer ser-
vice.
DANGER
Risk of electric shock.
Prior to all work on the appliance, switch off the ap-
pliance and pull the power plug.
Pull on the lever of the trigger gun; the device will
switch on.
Check whether the voltage indicated on the type
plate corresponds to the voltage of the mains sup-
ply.
Check the mains connection cable for damages.
Check setting at the spray lance.
Check water supply for adequate delivery rate.
Appliance ventilation: Switch the appliance on with
the high-pressure hose detached and operate
(max. 2 minutes) until the water exits the high-pres-
sure connection without bubbles. Switch off appli-
ance and reconnect high-pressure hose.
Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.
Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Slight leakage from the appliance pump is normal.
If the leakage increases contact the authorized
customer service.
The warranty terms published by the relevant sales
company are applicable in each country. We will repair
potential failures of your appliance within the warranty
period free of charge, provided that such failure is
caused by faulty material or defects in manufacturing. In
the event of a warranty claim please contact your dealer
or the nearest authorized Customer Service center.
Please submit the proof of purchase.
Call:
01-800-024-13-13
for help or visit our website:
www.karcher.com.mx
Subject to technical changes.
Care and maintenance
Clean the sieve in the water connection
Maintenance
Troubleshooting
Appliance is not running
Pressure does not build up in the appliance
Strong pressure fluctuations
Appliance is leaking
Warranty
Customer Support Mexico
Technical specifications
Electrical connection
Voltage
127
1~50-60
V
Hz
Power consumption
10 A
Protection class
IPX5
Protective class
II
Water connection
Max. feed pressure
1,2 MPa
Max. feed temperature
40 °C
Min. feed volume
8 I/min
Performance data
Working pressure
7,4 MPa
Max. permissible pressure
11,0
1600
MPa
psi
Water flow rate
4,5 I/min
Max. flow rate
6,0 I/min
Recoil force of trigger gun
9 N
Dimensions and weights
Length
538 mm
Width
293 mm
Height
303 mm
Typical operating weight
4,2 kg