English
5.906-432.0 Rev. 00 (06/15)
65
1 High pressure outlet (without pressure)
2 Manometer (without pressure)
3 Pressure retaining valve (closed)
4 Pump stands still
5 Rotary knob
6 Overflow valve (closed)
7 Reduction bore
8 Pressure switch "OFF" (closed)
9 Water inlet
10 Motor contactors (K1) (open)
11 Pressure switch "ON" (closed)
Note
The shown functions of the preessure switches and motor
contactor are for understanding purposes only.
In reality, the information from the two pressure switches is
transferred directly to the control electronics, which in turn
controls the motor contactor.
When the appliance is switched off and the gun is open,
the pressure is taken from the system and it is without volt-
age.
Both pressure switches as well as the overflow valve and
the pressure retaining valve closed.
The motor contactors are open.
6.32 Functional description of pressure switch
6.32.1 Appliance is switched off
0 Volt
6
1
3
4
7
8
9
11
5
10
2
Summary of Contents for HDS 7/12 M
Page 14: ...14 English 5 906 432 0 Rev 00 06 15...
Page 60: ...60 English 5 906 432 0 Rev 00 06 15 6 29 Functional diagram vacuuming operation...
Page 125: ...English 5 906 432 0 Rev 00 06 15 125 Circuit diagram 0 089 021 0 HDS 7 12...
Page 126: ...126 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 025 0 HDS 8 18 HDS 9 18...
Page 128: ...128 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 088 952 0 HDS 10 20 HDS 12 18...
Page 130: ...130 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 9026 0 HDS 13 20...