Horizontal vial
Vertical vial
Upper indicator light (red)
Middle indicator light (blue)
Buzzer
Lower indicator light (red)
Power indicator light (red)
Precision indicator light (red)
Precision key
Receiving window
Central red line
Central locating slot
Audio key
Power key
894-04 RED Detector
Safety and Warranty
1. Avoid use in a wet and dusty environment for extended
periods of time.
2. Keep receiving window clean. Avoid scratches.
3. Do not disassemble or modify the detector by yourself –
in doing so will void the warranty.
4. Storage temperature - 20° C ~ +60° C
5. Please avoid impact or vibration.
6. Please do not push roughly on the buttons.
7. Use only a dry clean, soft cloth to clean the detector.;
Do not use detergent or petroleum based scourers.
8. If the detector is not to be used for an extended period
of time - remove the battery.
9. Please do not operate this detector in strong electromagnetic
field or in an intense light environment.
10.This detector is also susceptible to sunlight, flashing lights,
fluorescent light, and alternating induction radio signals, and
the source of these signals can affect the actual measurement
of this detector, producing certain errors.
The performance parameters
Corresponding models:
This detector will detect red lines laser operated in pulse mode
at frequncy of 5 KHz (it will not detect rotating levels).
Detection range:
1 ~ 50 meters, vertical: 1 ~ 35 meters
Precision: High accuracy ± 1.5 mm.
Low accuracy ± 2.5 mm.
Power source: Laminated 9V battery
Dimensions:
164mm. (H) x 52mm. (W) x 27mm. (D)
Weight: 140 g (including battery)
USER MANUAL
Function - introduction
1. Bright indicator lights on the front and the reverse sides of
the detector.
Intense brightness signal lights used to indicate the laser
line position together with mutable audible signal.
2. Automatic shutdown.
Detector will shut down automatically if receives no laser
line and no key pressed for 7 minutes.
3. Low voltage alarm.
When the battery voltage is low, the power indicator light
will flash to notify the user to replace the batteries.
Directions for use
1.
Install the battery:
Insert the laminated 9V battery into the battery
compartment; ensure the proper contact with the terminals.
2.
The control panel:
Power key: To switch the detector ON and OFF. At start-up
the power indicator light will be lit and glowing steadily.
If the power indicator light is flashing - the battery voltage is
too low. Please replace the battery.
Precision key:
To switch between high and low accuracy. At
start-up, the detector will be low accuracy and the
corresponding indicator light is off. Press the key to switch to
higher precision mode. The precision indicator light will turn on.
3.
Audio switch button:
Turns the buzzer on and off.
4.
Detect the laser line:
Note:
When using this receiver, confirm that the multiline laser is
in the “PULSE” mode.
To detect the horizontal line place the detector vertically with
horizontal vial at the top, to detect the vertical line place the
detector with vertical vial at the top.
When the laser line is in the red receiving window, one of the
three red / blue indicator lights will light up to indicate the line
position. If the buzzer is on, a corresponding audible signal will
be heard at this time.
The red indicator light indicates to move the detector according
to the respective direction arrow in order to bring the laser line to
the middle of the receiving window. When the upper red light is
on – the detector should move down. When the lower red light
is on – the detector should move up. For vertical laser line
detection: when the right red light is on – the detector should
move to the left. When the left red light is on - the detector
should move to the right - see the table.
When the middle (blue) indicator lights up - the laser line is in the
middle of the receiving window overlapping with the central red
line, you can stop moving the detector and mark the line position
using the central locating slot.
Indicator light
UPPER/RIGHT indicator ON (RED) MIDDLE indicator ON (BLUE) LOWER / LEFT indicator ON (RED)
HORIZONTAL LINE
VERTICAL LINE
AUDIBLE SIGNAL
Laser line and central red line
overlapping
Laser line to the left of the central
red line: The detector should be
moved left until blue indicator
lights on.
Laser line and central red line
overlapping
Laser line to the right of the
central red line: The detector
should be moved to the right
until blue indicator lights on.
B-B-B-B-B
(less frequent beep)
B-------- (steady beep)
BBBBBBBB (frequent beep)
Laser line is below the central red
line - the detector should be moved
down until blue indicator lights on.
Laser line is above the central
red line - the detector should
be moved up until blue indicator
lights on.
(VERTICAL VIAL UP)
EN