6
DN1611-1809
KT-NCC Compliance Specifications
KT-NCC FCC &
IC Compliance
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received including interference that may cause undesired operation. This class A digital apparatus meets
all requirements of the Canadian Interference Causing Equipment Regulations. The KT-NCC is also
compliant with EN55022: 1994, amendment 1:1995, Class A.
UL 294
Compliance
Notice
•
The KT-NCC is UL 294 listed with EntraPass, KT-300 Door Access Controllers, IoProx Proximity
readers, and Trex request to exit devices
•
Each KT-NCC enclosure will be installed in a secured and protected location with tamper supervision
•
Each KT-NCC will be powered by a class 2 transformer such as the TR1640P/UL.
•
Each KT-NCC will be battery backed up with a KT-BATT-12, 12V/7Ah battery
•
Should additional sites or loops of KT-300 controllers be added, the installer must configure alarms to
be acknowledged in the event of communication troubles or failures
•
Each KT-NCC will be equipped with an AC powered LED installed outside the KT-NCC and
connected to an onboard relay, and visible at all time to monitor relay status, as per UL294.
UL 294
Performance
Levels
UL 1076
Compliance
Notice
•
The KT-NCC is UL 1076 Listed as a Commercial Proprietary Control Unit Accessory (Section 83.2),
with EntraPass and Redundant Server, alarm system features, KT-300 Door Access Controllers,
IoProx Proximity readers, and Trex request to exit devices – other sensor devices (temperature,
water level, etc.) may be used as long as they are also UL 1076 Listed.
•
The EntraPass and Redundant Server shall be running at all time, and manned 24 hours a day, 365
days a year – The EntraPass and Redundant Server will each have their own operator workstation.
•
Data processing equipment and office appliance and business equipment used as central
supervisory equipment station shall be Listed to Information Technology Equipment - UL 60950.
•
Should the EntraPass and/or Redundant Server be replaced, a UL 60950 listed computer must be
used.
•
The following recommended system requirements apply to the EntraPass Server, Redundant Server,
Video Vault, Card Gateway, SmartLink, and Workstation:
Operating Systems
•
Windows Server 2008 Standard / Enterprise
•
Windows 7 Pro / Enterprise / Ultimate. All in 32-bit and 64-bit versions.
Note:
Ensure all operating system have their latest Services packs and updates installed.
•
Dual Core processor
•
4GB RAM
•
AGP or PCI Express 8X graphics card with 75 MB memory and DirectX 9.0 support
•
10/100 Base-T network adapter EntraPass
Actual requirements may vary based on your operating system and configuration.
Model
Destructive
Attack
Line Security
Endurance
Standby
Power
KT-NCC
Level I
Level II
Level IV
Level I*
KT-CAB3000LDR
Level I
N/A
N/A
N/A
KT-CAB4000LDR
Level I
N/A
N/A
N/A
*Standby Power Level IV when powered by KT-300 or KT-400