5
Technical Specifications
Electrical Specifications
Specification
Description
AC Power Input
120/16 VAC, 40 VA, class 2 transformer
Battery Back-up
1battery 12 VDC, 7 Ah, supervised, provides up to 12 hours of operation, Kantech BD7-12
battery tested for 4 hours standby for UL294
Operating
Temperatures
From 2°C to 40°C (35°F to 110°F)
Cabinet Dimensions
(H-W-D)
29.9 cm x 28.8 cm x 7.7 cm (11-3/4 in x 11-3/8 in x 3 in) EMT 1.9 cm (3/4 in)
Cabinet Weight
2.4 kg (5.4 lbs)
PCB Dimension
18.3 cm x 12.18 cm x 5.20 cm (7-1/4 in x 4-3/4 in x 2-1/16 in)
Reader Types
Wiegand, proximity, bar code, magnetic, integrated keypad and others
Reader Power Output
12 VDC (11.1 VDC - 13.8 VDC) and 5VDC @ 175mA max, protected and supervised
Monitored Points
4 monitored points, NO/NC, w/without EOL’s (expandable to 12), use UL recognized tamper
switch on cabinet housing to conform with UL 294
Points Maximum Wiring
AWG #22 - 600 meters (2,000 feet)
Door Strike Power
12 VDC (11.1 VDC - 13.8 VDC), 250mA max each, supervised
Auxiliary Outputs
4 outputs, 25mA max each, open collector
Relay Controlled Output
2-relay controlled outputs, 25mA max each. Open collector swtiched to ground (use form “C”
relays Kantech #KT-RM1 if needed)
Auxiliary Power Output
11.1 to 13.8 VDC @ 175mA max, protected and supervised
Communication Ports
RS-232, RS-485 and Combus
Communication Speed
Up to 115.200 baud (automatic detection)
Firmware Flash
Memory
256K
RAM Memory
128K; protected by a lithium battery
Network Autonomy
Distributed data and processing
Certifications / Listing
FCC Part 15/ICES-003 Class B, Compliant with CE EMC Directive, UL Listed (UL294)
VOLTAGE OUTPUTS
MAXIMUM
CURRENT
ABSOLUTE COMBINED
MAXIMUM (N.A.)
ABSOLUTE
COMBINED
MAXIMUM (EU)
Lock Outputs 12 VDC
(11.1-13.8 VDC)
500 mA
(250 mA each)
Auxiliary Power (11.1 to 13.8 VDC)
175 mA