INSTALLATION MANUAL OPERATION MANUAL
KANNAD 406 AP-H
PAGE 210
JUL 24/2013
4. First power up
Perform the following tests:
1.
ELT operational tests:
• connect RCP to J1 and outside antenna to J2;
• switch the ELT from OFF to ARM;
• check that the Self-Test result is OK (one long flash).
2.
RCP operational tests:
Refer to 3. RCP operational tests, page 303
3.
406 & 121.5 MHz transmission tests (optional):
Refer to 4. 406 and 121.5 MHz transmission test, page 304
At the end of the first power up procedure, switch the ELT to ARM.
The ELT is now in stand by mode and ready to be activated either automatically
by G-Switch sensor if a crash occurs or manually by RCP (if any).
Note : switching to ON directly on the ELT front panel will also activate
the ELT.
5. Removal
• Switch the ELT to OFF (
Refer to Figure 205: Installation, controls and
).
• Disconnect the Remote Control Panel (or CS144) from the DIN12
connector (
Refer to Figure 205: Installation, controls and connectors
).
• Disconnect the outside antenna from the BNC connector (
205: Installation, controls and connectors
).
• Unfasten the self-stripping strap.
• Remove the auxiliary antenna.
• Remove the transmitter from the bracket.
Figure 207: Removing the transmitter