background image

 

1 of 4 

© 2005 

 U 506x - 12/05

U 506x 

12/05

Thermostat 506x

- User Brochure

Table of Contents

Display .............................................................. 1

Symbol Description ........................................... 2

User Interface ................................................... 2

View the Temperatures ..................................... 2

Adjust the Temperature Settings ...................... 3

Night Setback Operation .................................. 4

Select a Manual Override ................................. 4

Error Messages ................................................ 4

Cleaning the Thermostat  ................................. 4

Warranty ........................................................... 4

Features:

• 

•  Large Multilingual Display
• 

•  Remote Air Sensing
• 

• Manual Override
• 

• Floor Heating
• 

• Night Setback
• 

• Backlight

Display

Item Field

Displays an abbreviated 
name or symbol of the 
selected item

Number Field

Displays the current value 
of the selected item

Status Field

Displays the current 

status of the control’s 

inputs, outputs and 

operation

Menu Field

Displays the 

current menu

Summary of Contents for 506 Series

Page 1: ...erride 4 Error Messages 4 Cleaning the Thermostat 4 Warranty 4 Features Large Multilingual Display Remote Air Sensing Manual Override Floor Heating Night Setback Backlight Display Item Field Displays an abbreviated name or symbol of the selected item Number Field Displays the current value of the selected item Status Field Displays the current status of the control s inputs outputs and operation M...

Page 2: ...indoor air temperature SLEEP Shown while operating at the sleep temperature EXTERNAL NIGHT SETBACK Shown when external night setback signal is present HEAT Thermostat is in the heating mode of operation MANUAL OVERRIDE Shown when an override is manually selected OUTDOOR TEMPERATURE Shown together with the measured outdoor temperature INDOOR TARGET Shown together with the desired indoor air tempera...

Page 3: ... temperature Wake is the normal operating temperature Sleep is the operating temperature while a night setback signal or manual override is present Wake Sleep Press the up or down button to permanently adjust the Floor Minimum temperature Wake is the normal operating temperature Sleep is the operating temperature while a night setback signal or manual override is present Select either C or F Press...

Page 4: ...r ranty are the Purchaser s sole responsibility and obligation Purchaser shall indemnify and hold kanmor harmless from and against any and all claims liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers The pass through Limited Warranty does not apply if the returned Product has been damaged by negli...