Ultra-Fast 8x8 HDMI Matrix Switcher with
4K/60Hz & HDCP2.2
All Rights Reserved
Version: HDMX88-4K_2015V1.0
Page 1: ...Ultra Fast 8x8 HDMI Matrix Switcher with 4K 60Hz HDCP2 2 All Rights Reserved Version HDMX88 4K_2015V1 0...
Page 2: ...ual are acknowledged as the properties of the trademark owner No part of this publication may be copied or reproduced without prior written consent FCC Statement This equipment generates uses and can...
Page 3: ...install this product near water l Do not put any heavy items on the extension cable in case of extrusion l Do not remove the housing of the device as opening or removing housing may expose you to dan...
Page 4: ...4 2 1 Installation uninstallation of RS232 Control Software 5 4 2 2 Basic Settings 5 4 2 3 RS232 Communication Commands 6 4 2 4 EDID Management 10 4 2 4 1 Via RS232 commands 10 4 2 4 2 Via 4 pin EDID...
Page 5: ...8x8 HDMI Matrix Switcher with 4K 60 HDCP2 2 5 1 Supported Resolution 23 6 Panel Drawing 24 7 Troubleshooting Maintenance 24 8 After sales Service 26...
Page 6: ...MI outputs with 4K 60Hz l HDMI input ports support HDMI 2 0 support signal up to 4Kx2K 60Hz 1080p 3D and also compliant with HDCP2 2 l HDMI output ports support HDMI 1 4 capable to transmit 2560x1080...
Page 7: ...al TCP IP port for unit control IR IN input port for IR control signal connect with IR receiver RS232 Serial control port connect with control device EDID Switcher 4 pin EDID DIP switchers to set EDID...
Page 8: ...sources e g DVD to HDMI INPUTs with HDMI2 0 cables Step2 Connect HDMI displays e g HDTV to HDMI OUTPUTs with HDMI cables Step3 Connect speakers amplifiers to the AUDIO OUTPUTs with audio cables Step4...
Page 9: ...numerous commercial applications such as military medical and government audio video environments where swift reliable switching and distribution of high resolution HDMI signal is critical to meet pi...
Page 10: ...her with necessary input devices and output devices Then connect it with a PC installed RS232 control software Double click the software icon to run this software Here we take the software CommWatch e...
Page 11: ...mmands Lock Lock the front panel buttons System Locked Unlock Unlock the front panel buttons System Unlock Version Inquire the firmware version VX X X MessageOff Turn off command feedback from the com...
Page 12: ...nd y y 0 11 Save To F1 Recall y Recall preset command y y 0 11 Recall From F1 Clear y Clear preset command y y 0 11 Clear F1 EDIDG x Get EDID data from output x and display it on com port EDIDM X B y...
Page 13: ...016P 2D 5 1CH 10 2016P 2D 2CH EDID 8 3 EDIDPCM x Set the audio of input x to PCM in EDID database EDIDPCM1 EDIDH x B y Copy the EDID data from output x to input y If the EDID data is available and the...
Page 14: ...1 8 disable the SPDIF audio output of single output port l x 9 disable the SPDIF audio output of all output ports DigitAudio OFF With Output 4 Inquiry Commands Status x Check the input channel for out...
Page 15: ...Out 5 6 7 8 Audio N N Y Y 4 2 4 EDID Management The KanexPro HDMX88 4K provides a convenient EDID management to create effective communication between the display and sources In factory default status...
Page 16: ...EDID data 10 sets in total the chart below illustrate the 10 Embedded EDID data Custom EDID data max at 3 sets The chart below shows switcher status for custom EDID No 12 14 No Switcher Status EDID i...
Page 17: ...P port of the 8x8 Matrix Switcher and set its network segment to the same as the default IP of the Matrix Switcher 192 168 0 178 Figure 4 3 modify the IP of PC Controlled by PC s in LAN The HDMX88 4K...
Page 18: ...s network segment to the original one Step5 Connect the Matrix Switcher and PC s to the router In the same LAN each PC is able to control the Matrix Switcher asynchronously Then it s able to control t...
Page 19: ...TCPUDP 4 3 3 Control the HDMX88 4K via web based GUI Additionally the matrix can also be controlled via web based GUI which allows users to interact with Matrix switcher through graphical icons and vi...
Page 20: ...and user mode Administrator mode User name admin Password admin default setting User mode User name user Password user default setting Note Log in as admin can access more configuration interfaces tha...
Page 21: ...sible connection between every input and output users can carry on the connections by clicking corresponding button Buttons 1 8 at the right bottom corner provides quick saving and recall for overall...
Page 22: ...elect EDID Copy to enter the following interface Figure 4 11 Copy EDID The EDID of INPUT device can be gained from OUTPUT devices Step1 Select one INPUT port Step2 Select one OUTPUT port that you want...
Page 23: ...e top of the interface click Status to enter the following interface to modify the name and mode of this machine and then they will be display in LCD screen Figure 4 13 Status LCD 2 Select Button to e...
Page 24: ...ter the following interface to modify the name of scenes Figure 4 15 Status Scene 3 Network At the top of the interface click Network to enter the following interface to inquire and configure network...
Page 25: ...From the above interface turn on the Front Panel to lock all buttons of matrix and they will be locked to restrict any operation 4 3 4 TCP IP Configuration IP address subnet mask and Gateway of the M...
Page 26: ...gure 4 18 TCP IP Configuration 4 3 5 GUI Update GUI on the switcher can be updated online by going in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified...
Page 27: ...he Matrix Switcher to enter upgrade mode Press and hold button 2 3 when rebooting The power indicator will keep blinking in upgrade mode Step3 Double click the icon of upgrade software DfuSe Demonstra...
Page 28: ...Digital DTS DTS HD Max Resolution 4Kx2K 1080P 3D Transmission Distance 4Kx2K 60Hz 15m Power Supply DC 24V 2 5A Power Consumption 32W Full Load 2 2W Standby Dimension W H D 437 x 44 x 235 mm Weight 1 9...
Page 29: ...nce is switched off Send command x 1 To change HDCP compliance status The display doesn t support the input resolution Switch for another input source or enable the display to learn the EDID data of t...
Page 30: ...EDID data manually to make the resolution of the video source automatically compliant with the output resolution Cannot control the device by control device e g a PC through RS232 port Wrong connecti...
Page 31: ...ation or malfunction caused by oNormal wear and tear oUse of supplies or parts not meeting our specifications oNo certificate or invoice as the proof of warranty oThe product model showed on the warra...