background image

K&F PASSIO SUB 15

Important Information,
Please Read Before Use!

KLING & FREITAG GmbH
Junkersstraße 14
D-30179 Hannover
TEL +49 (0) 511 96 99 70
FAX +49 (0) 511 67 37 94
www.kling-freitag.de

User's Manual

Translation of the original instructions

Version 1.4

Released: 30.03.2017

Summary of Contents for PASSIO SUB 15

Page 1: ...mation Please Read Before Use KLING FREITAG GmbH Junkersstraße 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de User s Manual Translation of the original instructions Version 1 4 Released 30 03 2017 ...

Page 2: ......

Page 3: ... 3 4 Protecting the Speakers Operating Safety 7 4 Fuse in the PASSIO SUB 15 8 4 1 Replacing the Fuses 8 4 2 Replacing the Chassis 8 5 Configuration and Connecting Diagram 9 5 1 Combination with Top Speakers in 2 Channel Mode 9 5 2 Combination with Top Speakers in 1 Channel Mode 9 6 Dimensions PASSIO SUB 15 12 7 Measuring Diagrams 12 8 Technical Specifications 13 9 EC Declaration of Conformity 14 1...

Page 4: ...ctions may cause malfunctions or damage Tip This icon marks information provided for simplified use of the described products 1 2 About this Manual KLING FREITAG GmbH All rights reserved All specifications regarding the features of the described products and applicable safety guidelines provided in this manual are based on information available at the time of publishing We assume no responsibility...

Page 5: ...r stackings of identical enclosures 2 2x handle 3 Threaded stand flange with M20 threads for use with distance rod 4 Front grille 5 locking profiles for optional transport cover 6 2x SpeakOn connector 4 pin NLT4MP parallel 7 8x rubber foot 4 x on the side 4 x on the bottom 2 3 System Requirements Lab gruppen IPD 2400 or K F PLM 20k44 SystemAmp ProRental K F PLM 12k44 SystemAmp ProRental with K F C...

Page 6: ...c A technical expert who is responsible for the setup must evaluate and determine necessary measures including calculating the statics If necessary obtain expert proof of stability Stacked systems may not fall over even if they are inclined by 15 in each direction If this requirement is not fulfilled then it is necessary to take steps to achieve compliance Possible measures include strapping it to...

Page 7: ...by overloading the speakers or using the speakers without K F SystemAmp SystemRack we do not assume warranty and excludes liability for possible consequential damage The following signals may damage the speakers permanent high level signals with high frequency and continuous noise from feedback permanently distorted high level signals noises which occur when the amplifier is on while equipment is ...

Page 8: ...red tools 2 5 mm Allen key for loosening the terminals Instructions 1 Loosen the four screws on the terminal 2 Carefully pull the cables out of the speaker enclosure 3 Open the fuse holder 4 Replace the blown fuse 5 Push the cables carefully back into the enclosure 6 Pay attention to the correct alignment of the terminal Screw the terminal back on 4 2 Replacing the Chassis Required tools 3 mm Alle...

Page 9: ...SIO SUB 15 can only be combined in 2 channel mode with all K F top speakers when using a K F systemamp or systemrack To do so select the desired LS blocks for the top speaker in the K F systemamp or systemrack and combine these with the LS block for the PASSIO SUB 15 subwoofer PASSIO SUB 12 nächstes next SystemRack The 2 channel mode guarantees best sound quality and performance ...

Page 10: ... Selected LSBlock Controller CD 44 K F PASSIO 2xPassio PSub15 K F 2x Passio Passio Sub 15 K F GRAVIS 8 2xGra8W PSub15 K F 2x Gravis 8 W Passio Sub 15 K F GRAVIS 12N 2xGra12 N PSub15 K F 2x Gravis 12 N Passio Sub 15 K F GRAVIS 12W 2xGra12 W PSub15 K F 2x Gravis 12 W Passio Sub 15 K F GRAVIS 12XW 2xGr12 XW PSub15 K F 2x Gravis 12 XW Passio Sub 15 K F CA 1001 2xCA1001 PSub15 K F 2x CA1001 Passio Sub ...

Page 11: ...Version 1 4 Page 11 of 18 PASSIO SUB 12 PASSIO IPD2400 EU LS Block To the next IPD2400 EU IPD2400 EU Tip Depending on the top used you must make allowances in 1 channel operations for more or less significant volume losses as compared to 2 channel operations ...

Page 12: ...ser s Manual K F PASSIO SUB 15 KLING FREITAG GMBH 2017 Version 1 4 Page 12 of 18 6 Dimensions PASSIO SUB 15 7 Measuring Diagrams Frequency response Frequency response with system controller Frequency Hz ...

Page 13: ...m loudspeaker channel see matrix Components 15 long excursion chassis 75 mm voice coil with double centering internal and external ventilation Connection 2 x speakON 4 pol NLT4MP 1 1 IN parallel zu OUT Enclosure Design Frame reinforced enclosure 15 mm multiplex with highly resilient Polyurea synthetic black coating 2 ergonomical handles 8 rubber feet 8 stacking grooves for save stacking of identic...

Page 14: ... 5 SONA 6 SONA 8 SONA SUB SONS SUB II SW 112 SW 115D SW 115E SW 118E SW 212E These products are discontinued These systems are not covered by the Low Voltage Directive because of the rated voltage used We declare that the designated product s are in conformity with the protection requirements imposed by the following EU directives Electromagnetic Compatibility EMC Directive Low Voltage Directive T...

Page 15: ...User s Manual K F PASSIO SUB 15 KLING FREITAG GMBH 2017 Version 1 4 Page 15 of 18 10 Accessories Protective Cover PASSIO SUB 15 Distance rod 337 Transport Cover PASSIO SUB 15 ...

Page 16: ...reover a legally certified or official authority must perform a detailed inspection every four years Therefore be sure to maintain an inspection log Enter the values determined for each speaker and accessory during the periodic checks into this log This way relevant data are always at hand in case of inspection The log should also document maintenance measures and inspection intervals and contain ...

Page 17: ...ed on or after 24 March 2006 and must not be disposed of through household waste KLING FREITAG GmbH is legally registered as a manufacturer with the German waste equipment registration authority EAR The WEEE registration number is DE64110372 We substantiated towards the EAR that our products are for B2B trade only 13 2 EU Norway Iceland and Liechtenstein Don t dispose of waste electrical equipment...

Page 18: ...sions 12 Disposal 16 EC Declaration of Conformity 14 Fuse 8 InstallSound 5 Items Included 5 Maintenance 16 Measuring Diagrams 12 Operating Safety 7 Product Description 5 ProRental 5 Protecting the Speakers 7 Safety Instructions 6 Setup 9 SystemAmp 5 SystemRack 5 System Requirements 5 Technical Specifications 13 Wiring Diagrams 9 ...