Variometer — Manual
1.3
Options
Description
Value
Weight
57 mm: 150 g
80 mm: 200 g
Size (with connectors)
57 mm: 60 x 60 x 66 mm
80 mm: 82 x 82 x 66 mm
Panel hole (standard fit)
80 mm (3.15 inch)
57 mm (2.25 inch)
Altitude range
-500 to 15000 m, (-1500 to 45000 feet)
Operational voltage
8 to 32 V
Power consumption
1.2 W
Current
100 mA at 12 V, 50 mA at 24 V
Operating temperature
-30
◦
C
to +85
◦
C
Humidity
30 % -90 %, non condensing
Barometric sensor
24 bit, 10-1200 hPa, 20 cm resolution
Communication
CAN bus, 29 bit header, 500 kbit,
Kanardia protocol
Table 1:
Basic technical specifications.
1.3
Options
The instrument is available in two different sizes, different scale units
and different scale ranges. The scale units and range must be speci-
fied at the time of order.
The variometer is available in meters per second and feet per minute
units. The standard range is
±
10 m
/
s or
±
2000 fpm.
Different units and range is also possible with additional charges.
1.3.1
Display
Standard LCD display layout displays two values: Vario on top of
the screen and flight time on the bottom.
5
©
Kanardia
2015 - 2020