TECHNICAL DESCRIPTION
ULTRAFLOW® 54 DN150-300
Kamstrup A/S
·
Technical description
·
5512-876_M1_GB_12.2020
10
Ordering details of separate ULTRAFLOW® 54
Type number composition of separate ULTRAFLOW® 54
ULTRAFLOW
®
54. Type no: 65-5
- XX
XX - Y
Z - XXX
Dynamic range and flow
Connection and overall length
Output module
Supply module
Final assembly and marking
In addition to the basic variants listed in
, you must select output module (Y), supply module (Z) as well as meter
factor programming (CC) and pulse duration (E).
Type numbers of output and supply modules
Type number overview of output modules (Y) and supply modules (Z) for separate ULTRAFLOW® 54.
Y Output module
Corresponding supply module
1 Galvanically coupled module
0 (powered by MULTICAL
®
)
2 Galvanically separated module
0, 7, 8
3 Galvanically separated module, low power
0, 2, 7, 8
Z Supply module
Corresponding output module
0 No supply
1, 2, 3
2 Battery, D-cell
3
7 230 VAC supply module
2, 3
8 24 VAC supply module
2, 3
Table 5. Output modules (Y) and supply modules (Z).
The variant with galvanically coupled output module (Y=1) is solely for use together with MULTICAL®.
The variant with galvanically separated output module (Y=2 or 3) is used in the following situations:
1)
More than 10 metres cable length between MULTICAL® and ULTRAFLOW® is required.
2)
For flow sensor no. 2 in connection with MULTICAL®. If two flow sensors are used together with MULTICAL®,
one must include a galvanically separated output module (Y=2 or 3).
For further details see
paragraph
7.8.2 Calculator with two flow sensors
3)
ULTRAFLOW® is connected to other equipment/foreign calculators.
For more information on electrical connection, please see
paragraph 7.6 Electrical connections to MULTICAL®
Please note: Flow info cannot be read if output module with galvanic separation is used.