ULTRAFLOW® 54 DN15-125
16
Kamstrup A/S · Technical description · 5512-2464_D1_GB_09.2021
4.3.2
Type number composition of Pulse Transmitter and Pulse Divider
Pulse Transmitter 66 99 903 -
Pulse Divider 66 99 907 -
Y
Z - XXX
Output module
Supply module
Final assembly and marking
4.3.3
Output module and supply module
Y Output module
Corresponding supply module
2 Galvanically separated module
0, 7, 8
3 Galvanically separated module, low power
0, 2, 7, 8
Z Supply module
Corresponding output module
0 No supply
2, 3
2 Battery, D-cell
3
7 230 VAC supply module
2, 3
8 24 VAC supply module
2, 3
Table 7. Output module (Y) and supply module (Z) for Pulse Transmitter and Pulse Divider.
Pulse Transmitter and Pulse Divider are available with one of two different galvanically separated output modules.
Output module (Y=2) is used when extra-long cables are required. When connecting to MULTICAL®, a DC supply is
required as shown in
See also the Technical description of MULTICAL®, Flow
sensor with active 24 V pulse output. For output module (Y=2), battery supply is not an option.
Output module (Y=3) is intended for battery supply with a minimum battery life of 6 years. Output module (Y=3) is
selected by default.
When Pulse Transmitter and Pulse Divider are mains-supplied (24 VAC or 230 VAC) and connected via 3-wire cable to
MULTICAL®, both output modules can be used. See
and
, respectively.
For further information, see paragraph
6.11.2 Electrical connection of Pulse Transmitter and Pulse Divider