MULTICAL® 803
12
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
Diagram 1: Total typical accuracy of MULTICAL® 803, sensor pair and ULTRAFLOW® compared to EN 1434-1.
2.4
Electrical data
Calculator data
Typical accuracy
Calculator: E
c
±
(0.15 + 2/
∆Θ
) %
Sensor pair: E
t
±
(0.4 + 4/
∆Θ
) %
Display
LCD with white LED (32 x 63 mm) - 7 or 8 digits with 10 mm digit height
Resolutions
999.9999 - 9999.999 – 99999.99 – 999999.9 – 9999999
9999.9999 - 99999.999 – 999999.99 – 9999999.9 – 99999999
Energy units
MWh – kWh – GJ – Gcal
Data logger (EEPROM),
programmable
Logging intervals: From one minute to one year
Logger content: All registers can be selected
Standard logger profile: 20 years, 36 months, 460 days, 1400 hours
Info logger (EEPROM)
280 info codes can be read out via LogView, the latest 50 info codes can be read on the
calculator's display
Config logger (EEPROM)
50 config loggings
Clock/calendar
(with backup battery)
Clock, calendar, leap year compensation, target date
Summer/winter time (DST)
Programmable under country code
The function can be disabled so that “technical normal time” is used.
Time accuracy
Without external adjustment: Deviation less than 15 min./year from legal time
With external adjustment Deviation less than 7 s from legal time
every 48hours:
Data communication
KMP protocol with CRC16 used for optical communication
as well as modules.
Power of temperature
sensors
<
10
µ
W RMS
-6,0
-4,0
-2,0
0,0
2,0
4,0
6,0
0,01
0,10
1,00
10,00
T
o
l. [
%
]
q [m³/h]
MULTICAL
®
803 and ULTRAFLOW® qp 1.5 m³/h @
∆Θ
30K
Ec+Et+Ef (EN)
Ec+Et+Ef (Typ)