20.5
Radio disabled
Choosing module 99 and 98 (868/434 MHz) or module 97 (IoT/Sigfox), the Radio communication is disabled.
Radio OFF sign will be present in the display (not flashing). The radio can be activated with DataTool.
21
Communication (KMP)
The meter has an optical communication interface on the front. The interface communicates at 1200 baud and
can be used if an optical reading head is connected to METERTOOL and LogView.
21.1
Optical eye activation
In order to limit current consumption the optical eye is usually switched off. The meter's optical communication
is automatically switched on 4 sec. after having placed the magnetic optical reading head on the meter.
22
METERTOOL for Kamstrup Water Meters
METERTOOL is a PC program, giving access to change the customer selected parameters of a water meter
configuration and read its data memory without dismounting the meter from the installation.
Get further information and technical details on METERTOOL/LogView in document:
5512-1653_GB
–
Technical Description for METERTOOL & LogView