Pulse Interface for flowIQ® 3
100
To bring the meters into a diagnostic test mode, and during calibration and verification in test stands with pulse
interface, the Pulse Interface, type 66-99-143, is used.
The optical reading head is retained on the meter by means of a transparent plastic holder.
Optical support, type 6561-331
–
for Wireless meters
Optical holder type 6561-354
–
for wired M-Bus meters
Data from the meter is read by the optical reading head, and are converted in the pulse interface unit into high-
resolution volume pulses, which can be registered by a pulse receiver. When the optical reading head is removed
it takes 9 hours before the meter returns to normal mode.
Meter size
Q3 [m
3
/h]
Volume
[pulses/liter]
1.6 & 2.5
100
4.0
50
6.3
25
10
12.5
16
12.5
25
6.25
40
3.125
63
1.563
100
1.563
Pulse Interface, type 66-99-143, with
Optical Support type 6561-331
on flowIQ® wireless
Pulse Interface, type 66-99-143, with
Optical Holder type 6561-354
on flowIQ® wired
Pulse Supply:
3.5-30 VDC < 15 mA
Standby:
< 0.2 mA
Pulse width:
= 3.9ms
Frequency:
Max frequency of 128 Hz