TECHNICAL DESCRIPTION flowIQ® 3100
48
Kamstrup
A/S • Technical Description •
5512-1242_N
1_GB •
10.2019
17
Data loggers
17.1
Memory
flowIQ® 3100 has a permanent memory (EEPROM), in which the values of various data loggers are saved.
Loggers are read through the optical eye.
The meter includes the following registers:
Data logging interval
Data logging depth*
Logged value
Yearly logger
10 years
Counter register
Monthly logger
36 months
Counter register
Daily logger
460 days
Counter register
Info logger
50 events
Info code, meter reading and date
*
On specific modules the logger is disabled
–
see which ones in document no.:
The loggers are static ones. Thus, the register types cannot be changed. The same applies to the logging
intervals.
When there is no more space in logger (EEPROM), the newest logging will overwrite the oldest log.
.