Calibration Climatic chamber 

C3-50 

Summary of Contents for C3-50

Page 1: ...User Manual Calibration Climatic chamber C3 50...

Page 2: ...of income loss of business opportunities loss of use and other related exposures caused by incorrect use of product Warranty is valid for 13 months from date of shipping and includes spare parts and l...

Page 3: ...with touch display 23 5 3 Touch display 23 5 4 Basic setup 24 5 5 Program selection and Start 24 6 0 SETTINGS 26 6 1 Parameter settings Manual Program 26 6 2 Parameter settings Automatic Program 28 7...

Page 4: ...User Manual C3 50 4 11 0 DISMANTLING AND DISPOSAL 42 12 ATTACHMENTS 43 10 1 CE declaration of conformity 43 10 2 Electro drawings 43...

Page 5: ...sure about safe use of the product in your specific case do not hesitate to contact your dealer or us via info kambic com for further information or opinions In no event shall Kambic d o o be held li...

Page 6: ...erate the equipment in wet and condensing environment STABILITY HAZARD Do not load or affect product stability with heavy loads or climbing the product TRANSPORT HAZARD Transport the chamber only in o...

Page 7: ...e Verwendung des Ger tes in Ihrem spezifischen Fall unsicher sind z gern Sie nicht Ihren H ndler oder uns ber info kambic com zu weiteren Informationen oder Stellungnahmen zu kontaktieren Keinesfalls...

Page 8: ...sierender Umgebung betreiben GEFAHR DER SCHWERPUNKTVERLAGERUNG Keine schweren Lasten laden oder Stabilit t durch Zuladung oder Besteigen des Produktes beeinflussen GEFAHR DURCH TRANSPORT Transportiere...

Page 9: ...des doutes concernant une utilisation s re dans votre cas pr cis n h sitez pas contacter votre vendeur ou nous m mes via info kambic com pour plus d informations ou de conseils En aucun cas Kambic d o...

Page 10: ...nvironnement humide et pr sentant de la condensation RISQUE D INSTABILIT N affectez pas la stabilit du produit avec de lourdes charges ou en montant sur celui ci RISQUES LI S AU TRANSPORT Ne transport...

Page 11: ...st clara o tiene dudas en cuanto al uso seguro del producto en su caso particular contacte con su distribuidor o escr banos a info kambic com para obtener informaci n adicional u opini n Sociedad limi...

Page 12: ...o manipule el equipo en un ambiente h medo y de condensaci n RIESGO DE INESTABILIDAD No aplique carga ni desestabilice el producto con cargas pesadas No subir al producto RIESGOS AL TRANSPORTAR Transp...

Page 13: ...User Manual C3 50 13 info kambic com Kambic d o o o...

Page 14: ...User Manual C3 50 14...

Page 15: ...304 CrNi Exterior housing is made of galvanized material and powder coated Removable shelves are made of stainless steel mesh and are electro polished The seal between the chamber and the door is mad...

Page 16: ...used to circulate the air inside the chamber to provide temperature stability and uniformity Temperature control is controlled via a central microprocessor controller with PID controller Peltier Syst...

Page 17: ...the dry air purging system and drives saturated air in to the chamber DRY AIR PURGING SYSTEM Compressed air supply max 1MPa Air Supply pressure switch set to 0 25MPa Pressure regulator 1 set to 0 4MP...

Page 18: ...sic calibration is performed by the manufacturer If ordered the calibration report is delivered with the unit Calibration validation can also be done by the user because the appliance has a special su...

Page 19: ...ay resolution 0 1 Relative humidity set resolution 0 1 Relative humidity stability 0 2 21 C 50 Rh better than 0 8 full range Relative humidity uniformity Less than 2 full range Temperature control Cas...

Page 20: ...switch Power cord connection RS 232 Control panel with touch display Access Port Water Reservoir Condensation drain Chamber air exhaust Dry air system Peltier system Compressed air supply max 1Mpa Mai...

Page 21: ...r action requires longer period of open doors switch off the unite for this period Microprocessor controller has a special safety system which turns heaters off if temperature rises for more than 5 C...

Page 22: ...placed on a transport palette and only then lifted and transported with a vehicle Installation must be done in a dry well ventilated room Be sure that the seal is always clean and in superb condition...

Page 23: ...lay START button STOP button LCD touch display Power LED Operating LED Button no function Process graph Firmware Parameters display Numerical keyboard Menu entered indication Menu button Exit Clear En...

Page 24: ...6 Select the preset program and press START button Step 7 From this moment on the device runs completely automatically Step 8 Press STOP to stop the device 5 5 Program selection and Start Turn on the...

Page 25: ...Time set to 30 minutes when temperature and Rh reaches the tolerance area the time count down starts See special settings Tc 38 3 C 40 C Current chamber temperature is 38 3 C set chamber temp 40 C Rh...

Page 26: ...program starts immediately Parameters for manual program can be set while in operation 1 START PROGRAM 2 MANUAL 3 PROGRAM SETUP 4 SPECIAL SETUP 1 SELECT PROGRAM 0 MANUAL 1 50 AVTO Program name PROGRA...

Page 27: ...mber temperature Set desired chamber temperature temperature range is limited by producer 4 Relative humidity Set desired relative humidity in a chamber On display you can see an available humidity ra...

Page 28: ...RAM 1 AVTO PROG 1 SETUP DELAYED AUTOMATIC START WITHOUT DELAY PROG 1 SETUP DATE OF DELAYED START OFF PROG 1 SETUP STEP 1 CHAMBER TEMPERATURE 40 C PROG 1 SETUP STEP 1 CHAMBER 10 98 HUMIDITY 80 PROG 1 S...

Page 29: ...cycling options the main display will show Meaning S 2 this number will indicate which step number of steps setting of the program is currently under execution 7 20 20 number off all steps that need t...

Page 30: ...lways be set in combination with date of delayed start ATTENTION The date of the delayed start should always be set in combination with time of delayed start PROG 1 SETUP DELAYED AUTOMATIC START WITHO...

Page 31: ...ure in the chamber changes C min 12 Duration time Set desired duration time in time range from 1 min to 1440 min Duration time can also be set endless under 1 min or above 1440 min If you selected mor...

Page 32: ...up menu Display Press number to enter sub menu time setup Display To change value under blinking line press to move blinking line press To save and exit setting press 1 START PROGRAM 2 MANUAL 3 PROGRA...

Page 33: ...TART PROGRAM 2 MANUAL 3 PROGRAM SETUP 4 SPECIAL SETUP 4 1 TIME SETUP 2 CORRECTION SETUP 3 USERS PASSWORDS 4 PROGRAM COPY 2 ENTER PASSWORD AND FINISH WITH ENTER PASSWORD 0 0 ATTENTION See chapter 7 4 S...

Page 34: ...TOLERANCE IN HUMID RANGE 5 C 5 6 7 PID AIR Rh Regul Kp 6 0 C 6 0 Ti 150sec 150 Td 0 0 PID TEC Chamber Kp 30 0 C 30 0 Ti 50sec 50 Td 0 0 SPECIAL SETUP CICLE SERIAL NUMBER 13 SPECIAL SETUP DISPLAY CONTR...

Page 35: ...e is in set limits For example Set temperature 50 C Set time 60 min Set START TIME COUNT IN RANGE 1 C The countdown will start when the temperature will be between 49 0 C and 51 0 C 8 Time count down...

Page 36: ...tor 1 00x 10 Chamber temperature PID settings Factory default values Kp Gain 2 0 Ti Integral time s 150 0s Td Rate time 0 0 11 Thermoelectric cooler chamber PID settings Factory default values Kp Gain...

Page 37: ...number 1 will be copied COPY TO PROGRAM 2 to selected program number 2 To move between parameters press to set value press To confirm copy press button for 3 seconds 1 START PROGRAM 2 MANUAL 3 PROGRA...

Page 38: ...ove set temperature In case of an error on this system a mechanical over temperature shut off device will disable heating If this happens the cause of overheating must be found and the over temperatur...

Page 39: ...al Low temperature stability uniformity check the door seal check the operation of the chamber fan check the cooling ribs inside outside check the temperature sensor Increased noise check the Peltier...

Page 40: ...outside surfaces of the chamber clean For cleaning use some soft cleaning detergents and soft cloth Clean the rear cooling fan and cooling ribs Check and remove condensate under rear cooling ribs Mai...

Page 41: ...w the cooling of Peltier cooling system via its rear fan Additional space or relocation of the apparatus may be necessary when carrying out any maintenance or servicing The user must provide electrica...

Page 42: ...with your other household waste Instead you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical...

Page 43: ...User Manual C3 50 43 12 ATTACHMENTS 10 1 CE declaration of conformity 10 2 Electro drawings...