- 18 -
Boiler sold
by:
Company
Sales date:
Address
Phone
Boiler
installed by:
Company
Address
Phone
Foreman
(name, last name, signature)
In case of a
breakdown
contact
Company
Address
Phone
Manufacturer
UAB “Šiauli
ų
tauro kalvis”
Pramon
ė
s 15,
LT-78137 Šiauliai, Lithuania
Phone: (+370 41) 540556
E-mail: [email protected]
- 3 -
KALVIS – 6MPP 2009.05.18
ATTENTION !
Get acquainted with this technical certificate before installing the boiler
.
It
shall help you to mount and operate the boiler as efficiently as possible
.
1.
Basic engineering data
Central heating boiler with pellet burner „
Kalvis-6MPP
“ (hereinafter
referred to as the boiler) is used for heating various premises with installed
central heating system with enforced water circulation.
Boiler combusts 6-8 mm diameter saw dust pellets, or may be used as
a solid fuel (coal, fire-wood) fired boiler, when burner is removed and
protection is mounted.
Main technicla data
Table 1
Name of parameter
Parameter value
Fuel fired
Saw dust pellets
(max diameter
∅
6-8 mm)
Fire wood, waste
wood, coal, saw
dust and peat
briquettes, coal
Heated area, up to m
2
200
Fuel load, dm
3
470 50
Max wood length, mm
380
Combustion duration*:
- wood fired, h.
- coal fired, h.
130
3
6
Fuel consumptio per heating season, pellets /wood m³
7 - 8
20 - 25
Nominal output, kW
20 - 25
Efficiency, no less than:
- firing wood, %
- firing coal, %
80
72
78
Water pressure in the boiler, no greater than, MPa
(kgf/cm²)
0,15 (1,5)
Water volume in the boiler, l
86
Water temperature control range, °C
55 – 90
70-90
Minimum recommended water temperature in the boiler
during operation, °C
65
Recommended water tmeperature during operation, ºC
70-90
Minimum chimney draught, Pa
15
25
Smoke outlet dimensions, mm
Ø198
Loading dimensions, mm
270 x 400
Voltage, V
230
Electric capacity (motor + fan), W
90 + 57
Electric protection grade
IP 40
Loading hole diemnsions: H×B, mm
270 x 400
Overall dimensions, not greater than:
height x dempth x lenght, mm
1390 x 950 x 2260
Mass, not gretaer than, kg
365
* Combustion duration depends on fuel type and quality, humidity, external conditions
and other factors.
Firing wood with moisture content of over 30% is not recommended.
Summary of Contents for 6 MPP
Page 9: ...12 9 KALVIS 6MPP 2009 05 18...