KPS SERIES
Maintenance
M-UK-KPS--06
11/02/03 Page 95 of 138
KALTENBACH
5.1.2
Lubrication
•
Linear guiding
The linear guidings are factory prepared. The linear bearings are lubricated with
grease, and is equipped with a lubrication cassette, filled with oil.
Timing interval for lubrication is 3 to 5 year depending on usage
The cassettes can be greased by the lubrication-nipple, see picture lubrication.
The lubrication cassettes need to be replaced after 3 to 5 years .This must be done by
a qualified engineer
•
Ball screw
The Ball screw units are equipped 2 two lubrication blocks, see picture lubrication
Timing interval for lubrication is 6 months.
•
Knife and punch unit guiding
Timing interval for lubrication is 0,5 to 1 year depending on usage
•
Lubrication Points
The lubrication points are marked with yellow labels.
The following table shows the labels and matching description:
Label Description
Bring an Oil or Grease Gun on the lubrication nipple
Use a Brush to bring Grease onto the lubricate point
Use an Oilcan to lubricate