17
EN
II
I
III
a)
To set the water temperatur
e in the boiler/thermostove, pr
ess the
key
. Incr
ease or decr
ease degr
ees with keys
and
.
b)
To set the desir
ed temperatur
e in the r
oom (using the pr
obe on the boar
d) pr
ess the
key
. Incr
ease or decr
ease degr
ees with keys
and
.
c)
To set the work power pr
ess the
key and adjust it with the
and
keys.
The rinsing fr
om the stand-by state occurs automatically when a heat incr
ease is r
equir
ed to r
etur
n to satisfy the chosen stand-by condition (when
this is set to ON) or when ther
e is a health risk.
I =
Valve motorization
(4 - 5 - 6
)
II =
External thermostat O
N / OFF
or
stand-by type 3 (optional) (
1
)
III =
ON / OFF thermostat on
AC
S tank (
2
)
3 vi
e
3 wa
y
comune - N
common -
N
Lato sanitatio
DHW side
Lato riscaldam.
heating side
Sond
a
sup.
puffe
r
Puffer
uppe
r
prob
e
Termostat
o
estern
o
External
thermostat
Sonda accumulo
sanitario o sonda inf. puffe
r
DHW probe or puffer
lower prob
e
1
2
3
4
5
Terminal block:
numerical correspondence
for the v
arious electrical connections
.
6
Scheme 01:
the boiler/thermostove is connected to a domestic hot water tank and to the heating cir
cuit.
During the “WINTER” mode the boiler/thermostove is switched of
f when the contact (thermostat) below is satisfied. The boiler/thermostove is
switched on when the contact (thermostat) detects a temperatur
e below SET ACS - ΔT (ΔT can be set by technical parameters).
By setting the “SUMMER” mode the temperatur
e is consider
ed always satisfied.
The scheme is indicative and wants to demonstrate only the components that can be managed by the boiler/thermostove. Any r
elay pumps
must be contr
olled separately fr
om the boiler/thermostove.