5. Lighting the fireplace
45
Heat Pure 90 3-sided, 65 corner
Position the logs in an A-shape with
the horizontal log at the base.
Heat Pure 80 tunnel and Heat Pure
105 tunnel
Place 4 logs of approx ca. 30cm long in
a cross shape in the centre of the
fireplace.
When the logs have been burnt, position new logs on the glowing bed in
the same way as explained above. Take the amount of wood indicated
per hour into account.
Open door use
Heat Pure 65 corner, 90 corner right and left
These appliances can be used with the door open or closed. If you use
the appliance with the door open, we strongly advise you to remove the
baffle plate in order to guarantee optimal pull of the flue gasses.
By definition, the 3-sided and corner models are less suitable
for use as an open fire than the front opening models. If the
Heat-Pure 65 corner, 66 3-sided, Heat Pure 90 corner or Heat
Pure 90 3-sided models are used with the door open, smoke
may be blown into the room even if both baffles have been
removed.
The degree to which you can successfully use the appliances
open greatly depends on the flue duct and the draught it
exerts.