47
48
5
Troubleshooting
5.1
Solutions flowchart – Fera manual control
Is ignition sparking?
Does the pilot light come
on when ignition
button is held pushed in?
Does the pilot light stay
on when ignition
button is released after
20 seconds?
Burner bed comes on
The Fura burns very blue.
(It needs ±30 minutes in
order to heat up
completely.)
Please contact your dealer
about other problems.
Check that ignition cable is
hanging free and not clamped
against an iron component, or
this sparks continuously.
Check that the gas tap is turned
on, or whether there is a blockage
in the gas supply.
The thermocouple is broken.
Contact your dealer.
Is the ignition knob turned on
fully? (It must be turned to
the big flame)
There may be turbulence in the
pilot light, which means it is being
blown away. This could be
because the chips are lying in
front of the pilot light. Reposition
them and try again.
Check the flue
connection: does this comply
with Kal-Fire’s installation
conditions?
No
Contact your dealer.
Check whether the distance between
ionization pen and thermocouple is not
too great to spark across. If necessary,
bend closer.
Yes
Yes
No
No
No
No
Yes
No
Yes
No
Yes
Yes
No
Yes
No