4. Manually route the new drive belt over the pulleys without using force.
5. Tension the drive belt. Ensure that the drive belt is correctly positioned in its guide.
A belt that has been replaced may not be used again.
After running for two to three hours, check the belt tension again.
Old belts should be disposed of in accordance with the latest environmental regulations.
Putting in operation:
1. Replace the belt guard.
2. Reconnect the negative battery terminal.
3. Close the doors.
10.3.9 Battery maintenance
➤ Check the charging system if the battery discharges without reason.
10.3.9.1 Safety
WARNING
Danger of acid burns from escaping electrolyte!
➤ Wear appropriate protective clothing including acid-proof rubber gloves.
➤ Always wear eye and face protection.
➤ Do not tip the battery. Electrolyte may run out of the vent holes.
➤ Work with caution.
When working on the battery comply with the following safety signs:
A warning label with safety signs is attached to the battery.
Fig. 51 Safety signs - warning stickers on the battery.
10 Maintenance
10.3 Engine maintenance
118
Operator manual Portable compressor
M 64
No.: 9_5898 26 E