7.9.7.3 Activating the «remote control» key
Precondition Password level 2 is activated,
Menu
< Configuration ➙ Pressure control ➙ Load control > is selected.
1. Press «UP» repeatedly until
Key remote is displayed as the active line.
2. Press «Enter» to switch into setting mode.
Check box flashes.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.2.3 Load control
Menu
·········
Remote mode : pA/pB RC
Key remote : ☑
Active line
·········
current pB
3. Use the «UP» key to activate the check box.
4. Press «Enter» to accept the setting.
The «remote control» key can be used.
5. Press the «remote control» key to enable remote mode.
Result The operating mode is now configured.
7.9.8 Configuring master control of compressors regulated by pressure switch
➤ Configure the master control as previously described.
7.9.8.1 Configuring master control via floating relay contact
Requirement:
A machine with SIGMA CONTROL 2 (e.g. series BSD) and a conventional machine without
SIGMA CONTROL 2 of the same capacity are to run in sequence as base load or peak load ma‐
chines.
Proposal:
■ Set/adjust the clock program or clock on SIGMA CONTROL 2 .
■ Select local mode with time control pA/pB Clock or clock pA/pB Cycle.
■ Set the system setpoint pressures pA and pB analogous to the required values. They must be
identical to the pressure switch settings on the machine without SIGMA CONTROL 2 .
■ To make the setpoint changeover between the two machines possible, a floating relay contact
must be assigned to the selected local operating mode. An auxiliary contactor can be ener‐
gized via this contact to activate the pressure switches for pA and pB on the compressor with‐
out SIGMA CONTROL 2 . See the example wiring diagram below.
Overview
■ Making the electrical connection
■ Setting the system setpoint pressure pA and pB.
■ Configuring/adjusting the local operating mode
7
Initial Start-up
7.9
Configuring the machine for master control
112
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3
9_9450 03USE
Summary of Contents for ESD 352 SFC
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 171: ...KKW SSC 2 03 en 01 BA SIGMA CONTROL FLUID KKW SSC 2 03 01 20130805 113302...
Page 173: ......
Page 175: ...Contents ii Quick user guide Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03 USE...
Page 215: ...Contents iv Service manual Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03USE...
Page 392: ...KKW GBASE 1 00 en ERSATZTEILE 10357405_10 ESD 2C 20130903 115349...