2. Ensure that the machine is as level as possible.
The machine can be temporarily operated on a slope of not more than 15°.
Option oe:
Except for machines with closed floor pans - these should always be installed on as horizon‐
tal a surface as possible!
3. Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance. The operator panel with the «QUICK STOP» push-button must be accessible and with‐
in reach at any time.
4.
Fire hazard from build-up of heat and hot exhaust system!
Insufficient clearance above the machine may well cause heat build-up that could damage the
machine.
➤ Do not position the machine directly under a low roof or covering.
➤ Ensure always sufficient ventilation space around the machine.
5. Ensure there is enough free space all round and above the machine.
6. Keep air inlet and outlet openings free of obstructions so that the cooling air can flow freely
through the machine.
7. Install the machine ensuring that
■ exhaust gases and heated exhaust air can escape freely.
■ Do not allow exhaust gases and heated cooling air to be drawn into the compressor.
Note the wind direction! (see figure 19)
■ Ensure the unimpeded intake of fresh air (air intake, cooling air).
8.
Ambient temperature too low.
Frozen condensate and highly viscous engine or compressor cooling oil can cause damage
when starting the machine.
➤ Use winter grade engine oil.
➤ Use winter diesel fuel.
➤ Use low viscosity compressor cooling oil.
9. At ambient temperatures below 32 °F, follow the instructions in chapter 7.4.
5.3 Option rx
Machine with stationary frame structure
Stationary machines mounted on a frame may be installed on the load platforms of trucks.
For safe footing, the machine must be fixed to the load platform via bolt-down anti-vibration mounts
(bonded rubber/metal elements) for safe footing.
Prerequisites for the installation on truck platforms:
1. Follow the vehicle manufacturer's loading guidelines for safe operation and transportation.
2. Ensure there is enough free space around and above the machine.
3. Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance. The operator panel with the «QUICK STOP» push-button must be accessible and with‐
in reach at any time.
4. Keep air inlet and outlet openings free of obstructions so that the cooling air can flow freely
through the machine.
5
Installation and Operating Conditions
5.3
Machine with stationary frame structure
54
Operator Manual Screw Compressor
M114 SIGMA CONTROL SMART
No.: 901765 05 USE