A belt that has been replaced may not be used again.
Check the belt tension after running for approximately 15 minutes.
Old belts should be disposed of in accordance with current environmental regulations.
Putting in operation
1. Replace the belt guard.
2. Reconnect the negative battery terminal.
3. Close the canopy.
10.3.7 Having the anti-vibration mount checked
Anti-vibration mounts are elastomer metal elements, that are used, for example, for vibration-
dampened bearing of the drive of construction machines. They consist of two U-profiles that are
fastened to each other through an elastomer.
Fig. 41 Example for anti-vibration mount of drive engine
1
Anti-vibration mount
2
Bottom U-profile
3
Elastomer
4
Top U-profile
➤ Have the anti-vibration mount of the drive engine checked by an authorized KAESER service
representative.
Elastomer of anti-vibration mount is destroyed or porous.
➤ Have the anti-vibration mount replaced by an authorized KAESER service representative.
10.3.8 Battery maintenance
➤ Check the charging system if the battery discharges without a reason.
10.3.8.1 Safety
Danger of acid burns from escaping electrolyte!
➤ Wear appropriate protective clothing including acid-proof rubber gloves.
➤ Always wear eye and face protection.
➤ Do not tip the battery. Electrolyte may run out of the vent holes.
➤ Work with caution.
10 Maintenance
10.3 Drive engine maintenance
No.: 9_9547 13 USE
Operator Manual Screw Compressor
MOBILAIR M27
113