Putting in operation:
1. Switch the «battery isolating switch» on.
2. Close the door.
Dispose of old parts and contaminated materials according to environmental regulations.
Starting the machine and performing a test run:
1. Switch the machine on and run it in IDLE mode for approx. 5 minutes.
2. Shut down the machine.
3. Wait until the machine has automatically vented.
Pressure gauge reads 0 bar!
4. Open the outlet valves.
5. Open the left-hand door.
6. Visually inspect for leaks.
7. Shut down the machine.
8. Close the door.
10.5.6 Changing the oil separator cartridge
The oil separator element cannot be cleaned.
The life of the oil separator cartridge is influenced by:
■ Contamination in the air drawn into the compressor
■ and adherence to the changing intervals for:
─ Cooling oil
─ Oil filter
─ Air filter
Material Spare parts
Cleaning cloth
Wrench
Precondition The machine is shut down.
The machine is fully vented, the pressure gauge reads 0 bar.
Machine is cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
The «battery isolating switch» is off.
10 Maintenance
10.5 Compressor
No.: 9_9425 01 E
Service Manual Screw Compressor
M170 SIGMA CONTROL MOBIL
133