10.13.1 Cleaning the solenoid valve
Fig. 35 Cleaning the solenoid valve
1
Solenoid valve
2
Screw
3
Coil
4
Armature
5
Spring
6
Piston
7
Housing
8
Connecting socket
9
Arrow showing flow direction
1. Remove the connecting socket from the solenoid valve.
2. Undo the screw and carefully remove the coil.
3. Clean the armature and piston.
Change the spring if damaged or worn.
4. Reassemble the solenoid valve and fix the connecting socket.
5. Open the user's shut-off valve between the machine and the air distribution network.
6. Start the machine and visually check for leaks.
10 Maintenance
10.13 Solenoid valve maintenance
74
Assembly and operating manual 2-stage piston compressor
EPC-2-G