Kaden KC17 Installer Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

Evaporative Air Coolers

Safety Information

Installation

Commissioning

Classic Evaporative Air Coolers:

KC17 | KC21 | KC27 | KC32

Low Profile Evaporative Air Coolers:

KL16 | KL22 | KL25 | KL28

Models

INSTALLER’S

MANUAL

Summary of Contents for KC17

Page 1: ...aporative Air Coolers Safety Information Installation Commissioning Classic Evaporative Air Coolers KC17 KC21 KC27 KC32 Low Profile Evaporative Air Coolers KL16 KL22 KL25 KL28 Models INSTALLER S MANUA...

Page 2: ...3 Cooler Hardware 8 3 1 Bends and Elbows 8 3 2 Dampers 8 3 3 Fix and Seal the roof flashing 8 3 4 Dropper Duct Installation Guidelines 8 4 Installation Low Profile KL Series 9 4 1 KL Series Dropper D...

Page 3: ...ty and Replenishment During Operation 16 9 5 Shut down Times 16 10 Dismantling 17 10 1 Removing the Front and Rear Pads 17 10 2 Removing the Side Pads 17 10 3 Dismantling the Framework 17 11 Commissio...

Page 4: ...4 Kaden Installer s Manual Evaporative Air Coolers This page intentionally blank...

Page 5: ...omers are fit for the purpose for which they are intended WARNING REGULATORY INSTALLATION This appliance shall be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3...

Page 6: ...ment and additional labour involved in accessing cooler installations will not be accepted for warranty purposes Avoid positioning the cooler near any source of smoke dust or objectionable fumes so th...

Page 7: ...zing water in pipes may occur For the owner s convenience an additional isolating valve may be provided at ground level to isolate the water supply The water supply pipe MUST BE supported and secured...

Page 8: ...the roof peak should be fitted with an additional water diverting channel on the dropper duct high side that extends beyond the dropper duct sides by at least 50mm see diagram below NOTE This diagram...

Page 9: ...opper duct Insert the dropper duct between the roof rafters see diagram Ensure the template levelling bracket is positioned on the high roof side of the dropper duct Rest the templates equally on the...

Page 10: ...that the base latching brackets four retract over the flange on both sides of the dropper to lock it onto the dropper duct Fold the end of all four latching brackets in towards the dropper box Using...

Page 11: ...while the unit is on the ground For detailed instructions please refer to 6 Fitting the Winter Seal on page 12 5 3 FITTING THE KC SERIES COOLER The Cooler should now be mounted into position Insert th...

Page 12: ...ot to scratch or damage the sides of the unit 3 The Winter Seal can only be installed one way up because they are counterweighted on one side If the Winter Seal blades are installed the wrong way up t...

Page 13: ...straight and that the stoppers on each mounting bracket are in the correct position preventing the blades from over pivoting Repeat steps 3 6 for the second Winter Seal blade 7 Ensure that both blade...

Page 14: ...ening in the backing plate connect the cable to the terminal connections on the backing plate before mounting it on the wall and re assembling the Networker Connect the cable to the Networker connecti...

Page 15: ...in order to disperse the waste water away adequately without causing damage or nuisance i e overflowing roof guttering accelerated corrosion There are two recommended options when connecting drainage...

Page 16: ...ightly differently If the Cooler has been OFF for longer than 15 minutes it will begin with a 2 minute Pre wet then turn OFF the pump and start the fan Depending on the room conditions and the wall co...

Page 17: ...ont and back pads as above then Disconnect the 19mm clear hose supplying water to the roof distribution spreader at the fitting in the cooler s base squeeze clip then pull to release Ensure that all t...

Page 18: ...ing commissioning run the pump for 30 minutes without the fan and then drain the tank fully This will prime the pads flush out some of the new pad odour and remove any foreign matter that may have set...

Page 19: ...ge size windows doors suggestive only Highest Fan Setting Lowest Fan Setting Low Profile Series Classic Series KL16 KC17 Two sliding windows or Five hinged windows 1 5 m2 0 9 m2 KL22 One door and a hi...

Page 20: ...1100 1100 1100 1100 1100 1100 Height Front 720 720 720 720 597 682 682 945 Height Rear 400 400 400 400 Minimum Dropper Box Length mm 900 1200 Angle of Dropper Box degrees 21 90 Dropper Box Size mm 550...

Page 21: ...21 For technical support please call 1300 4KADEN 1300 452 336 14 TECHNICAL SUPPORT...

Page 22: ...22 Kaden Installer s Manual Evaporative Air Coolers NOTES...

Page 23: ...23 NOTES...

Page 24: ...B063652 Rev A...

Reviews: