Technical data
4.1
Electrical data
Powador 39.0
TL3
Powador 39.0
TL3 M1
Powador 60.0
TL3
Powador 60.0
TL3 - XL - F -
SPD 1+2 OP
Powador 48.0
TL3 Park
Powador 72.0
TL3 Park
DC Input levels
Input levels (DC)
Maximum recommended PV
generator power
39 kW
60 kW
48 kW
72 kW
MPPrange@Pnom
340-800 V
480-850 V
480-800 V
410-800 V
580-850 V
Working range
200 V -950 V
Rated voltage
600 V
790 V
Starting voltage
250 V
Open circuit voltage
1,000 V
Max. input current
2
3 x 34,0 (102)
A
102 A
3 x 36,0 (108) A
3 x 34,0 (102)
A
3 x 36,0 (108)
A
Number of strings
1 (M) / 4 (XL)
1
1 (M) / 4 (XL)
Number of MPP controls
3
1
3
Max. short-circuit current (ISC
max.)
3 x 40.8 A
122.4 A
3 x 45 A
3 x 40.8 A
3 x 45 A
Input source feedback current
0 A
Polarity safeguard
yes
-
yes
String fuse
yes (XL vari-
ant)
no
yes (XL variant)
DC overvoltage protection
type 2 (XL) /
type 1+2 (XL
SPD 1+2)
type 2
type 2 (XL) / type 1+2 (XL SPD 1+2)
Powador 39.0
TL3
Powador 39.0
TL3 M1
Powador 60.0
TL3
Powador 60.0
TL3 - XL - F -
SPD 1+2 OP
Powador 48.0
TL3 Park
Powador 72.0
TL3 Park
AC Output levels
Output levels (AC)
Nominal power
33.3 kVA [@415V];
33.3 kVA [@400V];
33.3 kVA [@380V]
50.0 kVA [@ 415V];
50.0 kVA [@400V];
50.0 kVA [@380V]
40.0 kVA
[@277V]
60 kVA
[@277V]
Rated voltage
220 V / 380 V [3/N/PE];
230 V / 400 V [3/N/PE];
240 V / 415 V [3/N/PE]
277 V / 480 V (3/N/PE) *)
Voltage range: continuous op-
eration
304 V - 480 V [Ph-Ph]
330 V - 528 V [Ph-Ph]
Rated current
3 x 46.4 A [@415V];
3 x 48.1 A [@400V];
3 x 50.6 A [@380V]
3 x 72.2 A
3 x 48.2 A
3 x 72.2 A
Max. continuous current
3 x 51.1 A
3 x 76.5 A
3 x 51.1 A
3 x 76.5 A
2
The "Max. input current" is the maximal theoretical value for operation with full power when the feed-in power is
low. The device is limited to the maximum AC power.
The "Max. short-circuit current (ISC
max
.)" defines together with open circuit voltage (U
DCmax
) the characteristic of the
connected PV generator. This is the relevant value for string sizing and is the absolute maximal limit for inverter pro-
tection. The connected PV-Generator must be designed, that the max short circuit current is below or equal to of the
inverter ISC
max
. of the inverter under all foreseeable conditions. In no condition the design may result in a greater
short circuit current than ISC
max
. of the inverter Designing the PV generator [See section 7.6.4
Powador 30.0-72.0 TL3
Page 14