4.10.3 Connection work, alarm system
The following section details the electrical connections between the IP-Box and hazard alert
or intrusion detection system that must be implemented to operate the locking system Paxos
advance as a blocking element. If required, in- and outputs of the IP-Box that are not used can
be connected to the hazard alert or intrusion detection system in accordance with the details in
section 5.4 “External connections to the IP-Box”
.
Note the following:
–
Route all of the connection cables to the IP-Box through the relevant opening in the IP-
Box cover.
–
The following connection diagram illustrates the wiring of the hazard alert or intrusion
detection system with the relevant in- and outputs of the IP-Box in accordance with the
factory configuration. For this purpose, also observe the following information.
A
S3
8
4
AS384 Management-Suite Software
The AS384 Management-Suite Software can be used to reconfigure the functions of the in- and
outputs. If the functionality of the in- and outputs is reconfigured, ensure that the connections
to and from the hazard alert or intrusion detection system are connected to the correct
connections of the IP-Box.
Important! Input 1 must mandatory be set for tamper monitoring (factory configuration)
otherwise the operation of the blocking element is deactivated.
Connection diagram for operating the locking system
Paxos advance
as a blocking element (
factory
configuration
)
IP-Box
14
15
+
–
12...24 VDC
GND
12 VDC ... 24 VDC
700 ... 200 mA
GND
–
+
NC
6.8 kΩ
6.8 k
Ω
1
2
GND
IN1
1
2
3
9
10
Hazard alert/intrusion detection system
Uninterruptible
power supply
Locking status
Remote locking signal
(positioning of the contacts with remote locking activated)