Kaba Mauer GmbH
82132 Code-Combi B
Page 23
GB
2 Signals and what they mean
Plastic input unit:
Aluminium input unit:
Diagram 1: Input units
Symbol
Signal
Meaning
1 x
Green LED fl ashes once
Valid 6-digit code entered
Green LED remains lit up
Lock is ready for programming
3 x
Red LED fl ashes 3 times
Invalid code entered or entry
suspended by pressing
P
button
10 x
Red LED fl ashes 10 times
after
ON
button pressed
Insuffi cient voltage
1, 2, 4, 8 or
16 minutes
Red LED fl ashes every second for
1, 2, 4, 8 or 16 minutes
after
ON
button pressed
Lock is in blocked status
Red LED fl ashes every 5 seconds
Lock is in time delay status
3 x
Red and green LED fl ash
alternately 3 times
Lock was last opened with another
code
/
Red and green LED fl ash
accompanied by an acoustic signal
Plastic control unit:
cover plate removed for key
opening
Aluminium control unit:
battery compartment lid was
opened to change batteries or at-
tempt to tamper with lock (disman-
tling of the input unit)
/
Green LED fl ashes every 5 sec-
onds accompanied by an acoustic
signal
Lock is in opening window status
1 x
Acoustic signal sounds once
End of opening window period
2 x
Acoustic signal sounds 2 times
During programming new 6-digit
code entered
3 x
Acoustic signal sounds 3 times
During programming invalid 6-digit
code entered
green LED
red LED
bar handle
bar handle
combined green/red LED