background image

 

 

 

Model: 

UTA02505APK

 

OWNER’S MANUAL 

Automatic Pool Cover Pump 

 

 

 

 

Questions, problems, missing parts? Before returning to the store call  

K2 Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday

 

1-844-242-2475 

www.K2pumps.com 

 

Copyright © 2020, GP Enterprises Co., Ltd.                                                                                                            K2Man-22 (Rev. 11/26/20) 

 

Summary of Contents for UTA02505APK

Page 1: ... Automatic Pool Cover Pump Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 www K2pumps com Copyright 2020 GP Enterprises Co Ltd K2Man 22 Rev 11 26 20 ...

Page 2: ...es The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong grounding type receptacle Do not use this pump with a 2 prong wall outlet Replace the 2 prong outlet with a properly grounded 3 prong receptacle a GFCI outlet installed in accordance with the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician 1...

Page 3: ...eptacle does NOT limit the magnitude of fault current and will NOT prevent an electrical shock Replace damaged cord immediately 24 Risk of electric shock This pump has NOT been tested for use in marine areas NEVER place pump in pools while people are in the water Do NOT handle pump with wet hands or when standing in water or on a damp surface Pump is designed to be used in closed and covered pools...

Page 4: ... DANGER Extension cords may not deliver sufficient voltage to the pump motor Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water The use of an extension cord to power this pump is not permitted WARNING This unit is NOT designed for use as a sump pump or in sump applications This unit is NOT designed for use in septic tan...

Page 5: ...r gasket to minimize water leaks Attach a garden hose with a 3 4 in garden hose thread not included to the check valve If you would prefer to use a 1 1 4 in hose kit not included in order to pump water away more quickly WARNING Secure the discharge hose before plugging in the pump An unsecured discharge hose may whip possibly causing personal injury and or property damage Securely attach the hose ...

Page 6: ...ded 25ft rope to pull to shore loop Figure B C2 Place pump on pool cover near edge of pool Figure C If flotation device is used place pump at the lowest point on the pool cover where water will collect D1 Holding the provided 25 ft rope walk around pool until you are even with the pump on the opposite side D2 Pull the 25 ft rope towards you until the pump is in the center of the pool cover where w...

Page 7: ...al failure or pump failure NOTE Do NOT alter the pump to override the automatic water detector The shaft seal depends on water for lubrication Overriding this pump feature CAN cause the pump to run dry and MAY damage the shaft seal and cause pump failure CARE AND CLEANING WARNING Pump starts automatically Always disconnect electric supply before attempting to install service relocate or perform an...

Page 8: ...iented as instructed on check valve body TROUBLESHOOTING DANGER Electrocution Hazard Pump starts automatically Disconnect the power before attempting any repairs Failure to follow WILL result in serious injury or death Problem Possible Cause Corrective Action Pump will not start or run 1 Tripped home electrical breaker 2 GFCI tripped 3 Low line voltage 4 Defective motor 5 Dirty switch 6 Impeller o...

Page 9: ...r pick up delivery transportation or house calls However if you mail your product to a K2 Sales and Service Center for warranty service cost of shipping will be paid one way This warranty does not apply to products purchased outside of the United States including its territories and possessions outside of U S Military Exchange and outside of Canada This warranty does not cover products purchased f...

Reviews: