EN
2
Attention!
Before using the appliance please read the contents of this instruction.
Attention!
Children of 8 years old and upward intend this appliance for use and persons with reduced physical,
sensory or mental capabilities, or lack of knowledge, unless a person responsible for their safety
has given them supervision or instruction concerning the use of the appliance. Children should be
supervised to ensure that they do not play with the appliance. Cleaning and service of the device
shouldn’t to be made by children without supervision.
Safety requirements
Base on type of protection from electric shock the fans relate to the devices of class ll (220-240V/50Hz)
or class III (12V/50 Hz). The climate category «moderately cold» Type «4» (УХЛ4). The level of protection
against solid objects and water is IP 24.
Attention!
Specialists, who have a special allowance for such types of work, shall do connection of the fans to power
supply. The temperature of fan exploitation cannot exceed the indicated range (from +1C to +40C).
Avoid the installation of the fan to one ventilation main line with smoke-deflecting pipe from devices, having
fuel burners. In case of maintenance diagnostics, turn off the automatic breaker (S1 in OFF position) and call an electrician.
Attention!
All actions for connection, set up, maintenance and repair of the product have to be carried out only at
mains voltage removed (S1 in OFF position).
One-phase main, to which the fan is connected, must correspond to the norms in force. Stationary electric wiring must be
equipped with an automatic circuit breaker (S1 in the scheme). The connection is carried out through the switch (S2 in the
diagram) that is built into the stationary wiring. The gap between switch contacts at all poles must be not less than 3 mm.
In the option «-02» the switch (S3 on the scheme) is built in the fan. Before installation, it is necessary to make sure that
there is no visible damage of impeller, case, grill, and the flow passage of the case has no any extraneous things, which
may damage impeller blades.
Сorrect use
Axial duct domestic electric fan, axial duct domestic removable electric fan is designed to remove odors and excess
moisture from toilets, bathrooms and other small rooms, required ventilation.
Attention!
For the purposes of maintenance or complete replacement of the equipment, all fans must have detachable
fixing.
SYMBOL LEGEND OF OPTIONS
Legend
Name
-02
Axial duct domestic removable electric fans with the pull-chain switch of turning on/off of the power
supply or timer.
С
Axial duct domestic removable electric fans with back flow valve.
AT
Axial domestic fan with the mode of ventilation
S
Axial duct domestic removable electric fans with mosquito net
ET
Axial duct domestic removable electric fans with electronic timer
Example
D 5S C AT
dditional options can be combined or absent.