background image

 

 
Installing / Changing the 
Carbon Filter. 

 
For model 

K1009R/K1009RA

 

The Cooker Hood uses a pair 
of CARBON FILTERS to purify 
the air for the air 
recirculation function.   
 
You will find the round 
carbon filters are packed in a 
plastic bag besides the 
cooker hood. And the filters 
will attach to both sides of 
the fan motor (please see 
figures at bottom of page). 
 

The active carbon filters must  
be replaced regularly, at least  
once every three months,  
to allow normal operation. 
 
Before starting to fit the carbon 
 filter, turn the omni-polar  
switch off at the wall. 

 

 

 

 

 

 

 

CHANGING THE CARBON FILTER 

 
1)

 

Press the handle of the metal grease 
filter towards the rear part of the unit 
until it is released from the front 
housing, and remove it by pressing 
downwards (Fig. 2 - above). 

 

2)

 

Remove the old carbon filters by 
twisting them anticlockwise until they 
unlatch from the sides of the motor. 

 

 

3)

 

Place the new carbon filters (which 
have two fixing tongues), turning 
clockwise so that the tongues latch 
onto the motor’s sides. (Fig. 3 - left). 

4)

 

Reposition the anti-grease metallic 
filter grilles. 

 

Installing / Changing the Carbon Filter

 

Summary of Contents for K1009 SERIES

Page 1: ...ESTIC COOKING ONLY Installer Leave this manual with the homeowner Homeowner Cleaning Maintenance and Operating instructions on the coming pages RANGE HOOD ITEM NO K1009R K1009C K1009RA K1009CA REFERED MODEL NO 3388F MOTOR WITH UL CERTIFICATE ...

Page 2: ...talling Changing the Carbon Filter 9 10 INSTALLATION INSTRUCTIONS 11 19 ELECTRICAL CONNECTION 11 INSTALLING THE RANGE HOOD 12 ATTACHING THE HOOD 13 14 FITTING THE CHIMNEY 15 16 ATTACHING THE GLASS 17 INSTALLATION NOTES EXTRACTION PURIFYING VERSION 18 NOTE ON INSTALLING THE VERSION WITH LOWER BRACKET 19 TROUBLESHOOTING 20 WARRANTY 21 CONTENTS ...

Page 3: ...imensions of Chimney Section 10 75 12 00 square or 13 5 10 24 round Your stainless steel Cooker Hood is fitted with High extraction tangential motor Electrical button control operation push button optional 3 speeds 2 metallic grease filters 2 lights Extraction capacity 860 CFM Optional Extra 1 x Pair of Carbon filter for air recirculation MAIN PARAMATERS Rated Input 120V 60HZ Rated Power 226W or 2...

Page 4: ... as you handle your appliance especially during installation and cleaning DO NOT CLEAN IN BEHIND THE GREASE FILTERS o If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the sealed or balanced flue type o If other types of flue or appliances are fitted ensure that there is an adequate supply of air in the room ...

Page 5: ... the hood including replacing light bulbs Do not connect the ducting system of this appliance to any existing ventilation system which is being used for any other purpose Do not install above a cooker with a high level grill Never leave frying pans unattended during use as overheated fats and oils might catch fire Do not leave naked flames under the cooker hood Do not attempt to use the cooker hoo...

Page 6: ...ote The hood should be switched on at least as soon as you start cooking KEY 1 Motor operation Stop stop motor Low low speed Mid mid speed High high speed Light Light on off button This button controls the light KEY2 Motor operation Low low speed Mid mid speed High high speed Light Light on off button This button controls the light PLEASE NOTE THAT YOUR RANGE HOOD CAN BE USED EITHER IN RECIRCULATI...

Page 7: ...d intervals Build up could cause a fire hazard Never take out the grease filters and attempt to clean the space above where they are set ________________________________________________ Anti Grease Grille Your range hood includes an anti grease grille which helps absorb vapour suspended grease particles to protect your kitchen furniture from greasy residues The metal grille may become inflammable ...

Page 8: ...peat the process if needed Refit the grease grille once it has dried Refit the grease grilles when dry PLEASE NOTE DISCOLOURATION OF THE GREASE FILTER CAN TAKE PLACE WHEN CLEANED IN A DISHWASHER ETC Do not worry about the slight discolouration of the grille its performance won t be affected Let the filter grilles dry thoroughly before refitting them Maintenance Cleaning the Anti grease Filters on ...

Page 9: ... the metal anti grease filters see Figure 2 below and find the old bulb located in the light fixture up inside the exposed canopy Change the halogen bulb using only olive shaped spares with an E14 coupling max 40W PLEASE NOTE Defective bulbs should be replaced immediately Replace the metal anti grease filters Maintenance Changing the Light Bulb and Carbon Filter ...

Page 10: ...low normal operation Before starting to fit the carbon filter turn the omni polar switch off at the wall CHANGING THE CARBON FILTER 1 Press the handle of the metal grease filter towards the rear part of the unit until it is released from the front housing and remove it by pressing downwards Fig 2 above 2 Remove the old carbon filters by twisting them anticlockwise until they unlatch from the sides...

Page 11: ...normal operation Before starting to fit the carbon filter turn the omni polar switch off at the wall CHANGING THE CARBON FILTER 1 Press the handle of the metal grease filter towards the rear part of the unit until it is released from the front housing and remove it by pressing downwards Fig 2 above 2 To move the handle inside the cooker hood See FIG 2 2 Remove the old carbon filter away 3 Place th...

Page 12: ...nd fixed with a cable clamp o The cooker hood s power cable must be fitted upstream from the electrical connection using an omni polar switch with a contact distance of at least 3mm NOTE WARNING THIS APPLIANCE MUST BE EARTHED It should only be connected by a competent person using fixed wiring via a DOUBLE POLE SWITCHED FUSED SPUR OUTLET See the bottom picture on right wire diagram We recommend th...

Page 13: ...he position of the support holes that are to be drilled as shown in the figure below These support holes can be found on Fig 4 on next page marked as D with the anchoring holes marked as E Fig 4 on next page If you hood comes with an attached jig use that as a guide to make the marks for the screw holes INSTALLATION INSTRUCTIONS Installing your Range Hood PLEASE NOTE THAT YOU WILL HAVE TO DECIDE B...

Page 14: ... fixings rawlplugs in the holes and then screw the support screws halfway in see below figure at right 5 Hook the hood onto the screws see above figure and fasten it onto the wall tightening the support and anchoring screws the rest of the way in next page at top Rear view of your range hood INSTALLATION INSTRUCTIONS Attaching the Hood 8 ...

Page 15: ... cooker hood see below Then connect the discharge pipe to the coupling as shown below Remember that your ducting will have to match the specifications shown in the notes on Extraction Air Purifier Recirculation Modes on p 18 INSTALLATION INSTRUCTIONS Attaching the Hood ...

Page 16: ...he casing correctly on the back of the hood as shown as part X in Figure 4 at right 3 Fix casing A onto the hood using the two screws K supplied in the bag of accessories Figure 4 at right 4 Lift the mobile part B until it reaches the ceiling checking that it is perpendicular to the hood 5 Mark the side measurement of the mobile casing B and then lower it see below INSTALLATION INSTRUCTIONS Fittin...

Page 17: ...ith a 8mm diameter make two holes on the fixing marks you previously made see below 8 Insert the expansion fixings rawlplugs provided put bracket G see Fig 4 on previous page in position and secure it with the screws provided 9 Lift casing B up to the ceiling and secure it to the bracket G inserting the screws provided in the holes M Fig 4 previous page INSTALLATION INSTRUCTIONS Fitting the Chimne...

Page 18: ...ushing it in towards the wall Tightening the screws F again in the hole and connecting them to the unit Take care that the anchoring corner is firmly fastened tightening it well Re insert the ventilation tube with the coupling tube N PLEASE NOTE DO NOT OVERTIGHTEN THESE SCREWS OR YOU MAY DAMAGE DISTORT THE UNIT ATTACHING THE GLASS ...

Page 19: ... of a pipe __________________________________________________________________________________________________________________________________________________________________________________________________________________________ AIR PURIFIER RECIRCULATION OPERATION Installation Instructions The range hood can be converted to work as an air purifier in the event that there is no provision for an e...

Page 20: ...w the cooker hood is to be installed from the process shown on page 13 In Fig 6 below you will see an exploded view of your cooker hood and inset the bracketed connecting area of the hood N Hook or attach the hood to the bracket using the screws supplied and carefully check that it has been done properly A few hoods may be supplied with specific screws for vertical or horizontal adjustment Fig 6 I...

Page 21: ...is not set high enough The grease filter is dirty The kitchen is not ventilated well enough If the hood is set for recirculation check that the carbon filters have not expired If the hood is set for extraction check that the ducting and outlets are not blocked The range hood has switched off during operation The safety cut out device has been tripped Turn off the hob and then wait for the device t...

Page 22: ... usage of detergent sprayer Pollution made to the led parts glass parts and S S parts Incorrect installation misuse abuse or neglect Incorrectly fitted to insufficient or unsuitable power Taken apart or serviced by unauthorized service engineers or replaced with other manufacture s components For commercial use the maintenance and free service should be discussed with our authorized agent Beyond t...

Page 23: ...22 K Star International Group Inc K Star Electronic Appliance Inc Toll Free 800 893 2168 Email info kstarus com http www kstarus com ...

Reviews: