![K.H. DEWERT 2690XLE User Manual Download Page 7](http://html1.mh-extra.com/html/k-h-dewert/2690xle/2690xle_user-manual_648689007.webp)
Dewert User Manual 2690XLE/2695XLE/2890XL/2895XL – Updated 11.2021/3 MDR Page 7 of 15
2.7 Additional equipment
Nose opening
If a nose opening is upholstered in the head part as an optional equipment feature, the opening can be closed
with a cushion (optional). To open up the nose opening, reach under the head part when the table is standing
still and press the cushion out from the bottom upwards (a slight amount of pressure is required). To close it,
simply insert the cushion into the opening (a slight amount of pressure is required).
Paper roll holder (optional equipment)
The paper roll holder consists of a holding bar and angle mount brackets or retaining brackets. In addition to the
stainless steel bar, the paper roll holding bar consists of a spring-loaded stainless steel sleeve featuring a round
steel gripping disc at the end. To insert the holding bar, feed the guide cotter pin of the stainless steel bar into the
rear hole of the angle mount bracket/retaining bracket. Then push the sleeve with the gripping disc
against the spring force and feed the front guide cotter pin into the second hole. Then relieve the spring tension on
the sleeve. To release the paper roll holder, proceed in the same way.
3-sectioned head part (optional only with models 2890XLE, 2890XL/H, 2895XLE, 2895XL/H)
The 3-sectioned head part consists of an adjustable head part as described under 2.3 and additional
armrests, which can be lowered and removed steplessly, to the right and left of the head part. The clamping is
released by loosening the knurled screw located underneath each armrest. The armrest can now be pulled
down through a range of approx. 180 mm. Re-clamping takes place by subsequently tightening the knurled
screw. To remove the armrests, loosen the knurled screw located directly underneath the head part. The
complete armrest can then be pulled off the head part from the side. The armrests must not be used for
sitting. They only serve to support the patient’s arms.
2.8 Special features of models 2690XLE, 2695XLE
The tables for echocardiography treatment have a cut-out on the left-hand side
in the upholstered surface. It can be closed with a cushion. The cushion can be pushed out from the bottom
upwards (a slight amount of pressure is required). To close the cut-out, first place the cushion in the rear of
the cut-out and then press it down into the upholstered surface (a slight amount of pressure is required). The
lower side of the cut-out is not parallel to the upper side. There is a visible slant. The position of the cushion in
the cut-out is thus clearly identifiable and there is no risk of it being accidentally pushed out.
In addition, model 2695XLE has a second cut-out on the right-hand side of the upholstered surface.
Caution: Do not reach under the cushion or into the open cut-out during height adjustment. Always
remove instruments/equipment from the cut-out area before adjusting the height.
Potential equalisation connector
A potential equalisation connector according to DIN 42801 is attached to the long side of the underframe on
the left (side with the upholstery cut-out). This connection must be used if interference from electromagnetic
radiation can be seen on the monitors during the examination, which could falsify the measured values.
Despite compliance with the applicable EMC regulations, the use of highly sensitive examination equipment
can cause this minimal radiation to become visible. Only use connectors that comply with DIN. Through
additional wiring of the individual assemblies, there is conductive contact between them.
The potential equalisation connector is marked with the symbol
3. Additional accessories (for user-specific table configuration), in extracts
•
Twin castors Ø 100 mm, centrally lockable
Lowered underframe
•
Paper roll holder
•
Additional foot switch
•
Additional hand switch
•
Foot switch fixation on the underframe
•
Side rails
•
Side guard for side rails