Page 24
Version No.
in the Sys-Menu or by holding
down the ENTER key when switching ON the
monitor. Now the password is set to the
default value 0000. Attention: This reset also
affects all the adjustments in the menus which
have been made by the user, only the
loudspeaker parameter setups which are
stored in the Flash Rom will remain. (please
see the menu „Default adjustments“).
5 IR Control
In this menu the IR remote control can be
switched ON / OFF.
6 AES Stat. / Sample Rate
In this menu the clock frequency is shown,
which the O 500 C is locked to. In normal
mode, this will be 44,1 kHz for S-PDIF or 48
kHz for AES/EBU format. This is a straight
status display, just for user information, and
non-adjustable.
7 Version No. (Operating System)
In this menu the release number of the
operating system of the digital controller will
be displayed. In case of service this number
may be needed for reference or updates.
When activating the option
Reboot
via the
ENTER key, the digital controller will boot like
it does if you power-up the O 500 C.
A
ll
settings and presets in the individual menus
remain active. When the option
Initialize
is
selected, all individual settings in all menus
will be erased and the system will only work
with the default settings of the factory presets.
When pressing the ENTER key an additional
confirmation is necessary by pressing the
Main key. Otherwise, it is possible to turn back
by pressing the SYS key.
8 Service Section
This menu has no function in the O 500 C.
9 Version No. (Eprom)
In this menu the number of the DSP software
version will be displayed, which is stored in
the internal E-PROM.
10 Logo
In this menu it is possible to switch OFF the
illuminated K+H logo, which is located on the
left of the VF display. This selection is stored
in the main setup, too. (see Chapter 3.2, step
1)
3.4 EQ – Menu
(Eprom-Version-No. KH 1.038)
Description of the menu steps:
K+H O 500 C
- EQ Menu -
Menu headline
1 EQ Set (Room EQ section)
In this menu step the adjustments for a room
equalisation can be done easily. The settings
are made by pressing the +/- increment keys
on the remote control, the changes are done
imediately without confirming with ENTER.
By pressing the LEFT / RIGHT arrow keys
the cursor can be moved between the four
possible options of this menu ( for futher
explanations see chapter 5.1).
Options
Units
Default Settings
0
1
2
3
4
5
Low Cut [Hz]
30...80 [10] Hz
30
Bass EQ [dB]
-10...0 [2] dB
0
Mid EQ [dB]
-5...0 (1) dB
0
High EQ [dB]
-4...1 (1) dB
0
Gain [dB]
-24...0 dB
-3
EQ [on / off]
on
Type [HS12, HS6, LS12, LS6, Peak,
---
Peak
HP12, HP6, LP12, LP6]
---
...
...
Güte
0,1...6355
2
Frequenz [Hz]
---
(misc.)
Gain [dB]
-99...12 dB
0.0
13
Load EQ Setup
No. / Name
---
000 Default Setup
14
Save EQ Setup
Enter Setup Name / Enter Setup No.
---
Default Setup / 000
EQ 10
3
2
12
EQ 1
1
EQ Set
EQ
X
X
X
X
X
X
X
X
User Security Levels
K+H O 500 C
EQ Menu
No. / Name of Menu Step
0