background image

Introduction

 5

Backplane Slots & Functionality

Table  1-5: Backplane Slots & Functionality

Backplane PCI Express Bus Topology

Figure 1-1: Backplane PCI Express Bus Topology

Type of Slot

Qty

Slot 

Number

Bus

PXI Express Hybrid 

Peripheral Slot

4

2,3,4,5

Slots 2 and 3 support PCIe x1 Gen2 

link, and PCI 32-bit (33MHz 5VIO).

Slots 4 and 5 support PCIe x4 Gen3 

link, and PCI 32-bit (33MHz 5VIO).

Front Panel

PCI Express 

2.0 Switch

PCI Express 

3.0 Switch

PCIe Gen2 x4

PCIe Gen3 x4

TB3

USB Type-C

Port A

(USB-PD 60W)

TB3

USB Type-C

Port B

(USB-PD 15W)

Thunderbolt 3 

Intel JHL6540

PCIe-to-PCI 

Bridge

PCI Bus

32-bit 33Hz 

5VIO

PCIe x4 Gen3 
PCIe x4 Gen3 
PCIe x1 Gen2
PCIe x1 Gen2

2

3

H

4

H

5

H

H

Programmable MUX

SMBus Controller

Trigger Signal

SMB

Connector

SMBus

Trigger Bus

Summary of Contents for Thunderbolt PXIe-62314T

Page 1: ...PXIe 62314T Compact 4 slot Thunderbolt 3 PXI Express Chassis Manual Rev Rev 1 0 Revision Date November 3 2020...

Page 2: ...ii Revision History Revision History Revision Release Date Description of Change s 1 0 2021 3 1 Initial release...

Page 3: ...rising out of the use or inability to use the product or documentation even if advised of the possibility of such damages JYTEK is committed to fulfill its social responsi bility to global environment...

Page 4: ...or more information go to www P65Warnings ca gov Trademarks Product names mentioned herein are used for identification pur poses only and may be trademarks and or registered trademarks of their respec...

Page 5: ...l Sensors 17 1 3 4 PCI Express 18 2 Getting Started 23 2 1 Package Contents 23 2 2 Power Supply Budget Considerations 24 2 3 Cooling Considerations 24 2 4 Configure Settings for Cooling 24 2 5 Install...

Page 6: ...dix Maintenance 33 A 1 Installation Problems 33 A 2 FAQ 33 A 3 Basic Troubleshooting 36 A 4 Maintenance 37 A 4 1 Handling the Chassis 37 A 4 2 Cleaning the Exterior 37 A 4 3 Power Requirements 37 Impo...

Page 7: ...gure 1 7 Bottom View 11 Figure 1 8 PXIe 62314T Front Panel 14 Figure 1 9 PXIe 62314T Rear Panel 17 Figure 1 10 PXIe 62314T Backplane Thermal Sensor Positions 17 Figure 1 11 3U PXI Express Peripheral M...

Page 8: ...viii List of Figures This page intentionally left blank...

Page 9: ...MHz System Reference Clock 4 Table 1 5 Backplane Slots Functionality 5 Table 1 6 Operating Temperature 6 Table 1 7 Cooling 7 Table 1 8 Mechanical Dimensions and Weight 8 Table 1 9 PXI Express Slot Pin...

Page 10: ...x List of Tables This page intentionally left blank...

Page 11: ...maximum 22Gbps bidirectional data bandwidth for high throughput data transfer applications The PXIe 62314T offers USB Power Delivery functionality through Thunderbolt 3 ports supporting up to 60W powe...

Page 12: ...data bandwidth transfers up to 40 Gb s 1 Trigger I O port programmable from to backplane PXI Trigger Bus Smart fan temperature voltage fan monitor Backplane PXI Signals DC Power Output up to 160W com...

Page 13: ...0 C to 50 C 32 F to 122 F 160W DC input 16V 32V 120W DC input 9 12V Voltage Rail Maximum Total Current Load Regulation Maximum Ripple Noise 12V 15A 5 120mV 3 3V 12A 5 50mV 5V 12A 5 50mV 12V 1A 5 120mV...

Page 14: ...s Accuracy 1 ppm max 0 C to 55 C 32 F to 131 F Maximum jitter 2 41 ps RMS phase jitter 12kHz 20MHz Duty factor for PXIe_CLK100 45 to 55 Absolute differential voltage when terminated with a 50 load to...

Page 15: ...Gen2 link and PCI 32 bit 33MHz 5VIO Slots 4 and 5 support PCIe x4 Gen3 link and PCI 32 bit 33MHz 5VIO Front Panel PCI Express 2 0 Switch PCI Express 3 0 Switch PCIe Gen2 x4 PCIe Gen3 x4 TB3 USB Type...

Page 16: ...ent When all installed peripheral modules require less than 38W cooling capacity 0 C to 50 C 32 F to 122 F Indoor use only When any peripheral module requires more than 38W and less than 58W cooling c...

Page 17: ...le Module airflow intake Left side of chassis when facing chassis Module airflow exhaust Right side of chassis when facing chassis Peripheral Module Slot cooling capacity Maximum 58W per slot Minimum...

Page 18: ...8 Mechanical Dimensions and Weight All dimensions in millimeters Figure 1 2 Top View Item Detail Height 148 4mm 5 84 Width 207 9mm 8 19 Depth 220 5 mm 8 68 Net Weight 3 8KG 8 38 lbs Gross Weight with...

Page 19: ...Introduction 9 Figure 1 3 Left View Figure 1 4 Front View 235 20 220 50 142 40 200 40 148 40 207 90...

Page 20: ...10 Introduction Figure 1 5 RightView Figure 1 6 Rear View...

Page 21: ...Introduction 11 Figure 1 7 Bottom View 2 164 2 179 80 18 20 18 20...

Page 22: ...software services drivers sample programs and utilities for JYTEK PXI Express PXI system modules and chassis Please refer to the JYTEK PXI Platform Service user manual for more infor mation Measuremen...

Page 23: ...bpart A Class B ICES 001 Class B ICES 003 Issue 6 2016 AS NZS CISPR 11 Group 1 Class B emissions Item Detail Storage Ambient temperature 40 C to 71 C 40 F to 159 8 F Relative humidity 10 to 90 noncond...

Page 24: ...14 Introduction 1 3 Connectors I O and Controls 1 3 1 Front Panel Figure 1 8 PXIe 62314T Front Panel A B C D E F G...

Page 25: ...h Disables Smart Fan function Sets fan speeds of rear 3 fans to max RPM Auto Enables Smart Fan function Auto fan speed based on temperature detected by thermal sensors of PXIe 62314T D PXI Trigger I O...

Page 26: ...RONT MSTB 2 5 3 STF 5 08 1777811 NOTE NOTE Power button is disabled when Thunderbolt 3 port is connected to a power on host PC Power button function restores when host PC is power off or Thunderbolt 3...

Page 27: ...ane Thermal Sensors Positions of thermal sensors Figure 1 10 PXIe 62314T Backplane Thermal Sensor Positions NOTE NOTE For details about chassis temperature detection please see Chassis Status Monitor...

Page 28: ...CIe Gen3 switch fabric allowing PCI Express bus data streams between the Thunderbolt 3 ports and all peripheral slots NOTE NOTE Connector pin assignments of the PXI Express Hybrid Periph eral Slots co...

Page 29: ...Slots 4 and 5 are connected by a PCIe Gen3 x4 link All slots share the same PCIe uplink to the host PCIe controller via Thunderbolt 3 port Each slot can accommodate either a 3U PXI Express module Fig...

Page 30: ...e is a daisy chained bus that connects each peripheral slot with adjacent peripheral slots to the left and right The quantity of local bus lines is decreased from thirteen to one PXI_LBL6 and PXI_LBR6...

Page 31: ...8 trigger lines connecting all slots on the same segment providing inter mod ule synchronization PXI and PXI Express modules can exchange trigger or clock signals through the trigger bus allowing prec...

Page 32: ...inter module syn chronization The independent buffers drive the clock signal to each peripheral slot These common reference clock signals can synchronize multi ple modules in a PXI Express chassis PXI...

Page 33: ...is DC input connector DECA MC311 50803 The following accessories are available in the PXIe 62314T Kit ordered separately Thunderbolt 3 certified cable 0 7m 160W AC DC power adapter Power cord for US E...

Page 34: ...e airflow direction is from left to right as viewed facing the front of the chassis 2 4 Configure Settings for Cooling Heat ventilation is related to the installation location environmen tal temperatu...

Page 35: ...C notebook 4 Download JYTEK PXI Platform Services from the PXIe 62314T product web page Install the software package on the host PC notebook by running setup exe and following the on screen instructio...

Page 36: ...nel 5 Power on the host PC notebook and boot into Windows 10 6 Launch Thunderbolt utility of host PC notebook Set PXIe 62314T as a valid device to always connect NOTE NOTE In order to make sure essent...

Page 37: ...off the chassis CAUTION Not following the correct power on and power off sequences may result in events that cannot be properly handled by the host PC notebook BIOS operating sys tem and or installed...

Page 38: ...62314T defined in the PXISA PXI 6 Software Specification PXI Resource Manager A Windows background service following the PXI 2 and PXI 6 Software Specification to scan PXI PXIe controllers chassis an...

Page 39: ...itions including internal tempera ture fan speed and DC voltage can all be monitored via JYTEK ChassisWatch a Windows based utility for JYTEK PXIe chas sis monitoring and configuration Communication w...

Page 40: ...status monitoring configurable PXI trigger bus bridges and Smart Fan are introduced in the following sections For more information about ChassisWatch please refer to the JYTEK PXI Platform Services us...

Page 41: ...the default 50 C as an example fans run at 40 when all temperature readings are less than 25 C and begin ramp up when any reading exceeds 25 C Fans run at 100 speed if any temperature reading exceeds...

Page 42: ...B 45 C 113 F Highest chassis temperature at which fan speeds commence ramping up for final 70 temperature mark see C C 70 C 158 F Highest chassis temperature at which fan speeds reach maximum speed D...

Page 43: ...is securely plugged into the chassis power connector and power outlet wall socket power strip If the system fails to start when all installation conditions are met remove all installed peripheral modu...

Page 44: ...3 high speed protocols Thunderbolt 3 certified cables listed on the Thunderbolt 3 official website are required for Thunderbolt 3 connections between host PC notebook and the PXIe 62314T Q Instead of...

Page 45: ...y when hot plugging a Thunderbolt 3 connection when any driver installed on the host PC does not support dynamic resource allocation properly Steps for technical troubleshooting 1 Configure the Window...

Page 46: ...nnection the power button is locked when the host PC is connected and the system is powered on Power off the host PC and disconnect Thunderbolt 3 connection to unlock the power button Power LED blue i...

Page 47: ...the area in and around the chassis air intake apertures A 4 3 Power Requirements Make sure that the power cord and DC power input connector are in good condition before plugging it into the system It...

Page 48: ...38 Maintenance This page intentionally left blank...

Page 49: ...or when removal of a chassis cover is required for user ser vicing See Getting Started on page 23 Turn off power and unplug any power cords cables Reinstall all chassis covers before restoring power T...

Page 50: ...in a server room or computer room where access is Restricted to qualified service personnel or users familiar with restrictions applied to the location reasons therefor and any precautions required O...

Page 51: ...is our top priority Contact us should you require any service or assistance Shanghai Jianyi Technology Co Ltd www jytek com Website Service Telephone No Fax No Mailing Address 86 21 50475899 86 21 50...

Reviews: