background image

Button & SW

RUN State

1. Oscilloscope Mode

2. Frequency Meter Mode

3. FFT Mode

Button Function Summary

For detailed documents please
visit

www.jyetech.com

Quick Use Guide

Applicable Model: 09601, 09602

DSO 096 Oscilloscope

Panel & Connectors

Mode Navigating

Vertical Sensitivity
Switch 1

Vertica l Sensitivity
Switch 2

Test
Si gnal
Output

Coupl e Select
Switch

Signal
Input
Connector

Control Buttons

USB Connector

Power
Switch

Vertical
Position
Indicator

Battery Indicator

HOLD s tate

Couple

Vertical
Sensitivity

Time Base

Vertical & Horizontal
Position Adjus tment
Trigger Mode

Trigger Level
Adjustment

Trigger Slope

Trigger
Level
Indicator

Trig Point
Indicator

Horizontal
Position
Indicator

Power
Switch

Battery
Connector

LCD
Contrast
Adjustment

Programming
Header

Oscilloscope
Mode (default)

Frequency Meter
Mode

FFT
Mode

Scroll highlight bar to functin wanted
and press [OK] button

Mode Select Menu

Hold [MODE]
for 3 seconds

Press [MODE]

Pre ss [MODE]

Functions

[VPOS]

[HPOS]

[SEC/DIV]

[MODE]

[SLOPE]

[LEVEL]

[VPOS] hold

[MODE] hold

[SLOPE] hold

[LEVEL] hold

[+]

[-]

[OK]

[OK] hold

V.Sen 1 & V.Sen 2

Couple

Select VPOS

Select HPOS

Select TIME-BASE

Select trigger mode

Select trigger slope

Select trigger level

Adjust the selected param.

Enter HOLD state

VPOS alignment

Enter Function Select menu

Turn LCD backlight on/off

Enter Setting Select menu

Turn off device

Change vertical sensitivity

Adjust the selected param.

Change couple method

Button & SW

HOLD State

Functions

[VPOS]

[HPOS]

[SEC/DIV]

[MODE]

[SLOPE]

[LEVEL]

[+]

[-]

[OK]

Select VPOS

Select HPOS

Save waveform to buffer

Select trigger mode

Display buffer

Send screen

Adjust the selected param.

Exit HOLD state

Adjust the selected param.

Button & SW

Functions

[MODE]

V.Sen 1 & V.Sen 2

Couple

Change sensitivity

Change couple method

Enter Function Select menu

Button & SW

Functions

[MODE]

V.Sen 1 & V.Sen 2

Couple

Change sensitivity

Change couple method

Enter Function Select menu

[+] or [-]

[HPOS]

Change sampling rate

Change FFT size

Rev. 02

(1K Hz 5Vpp )

(V/Div)

(Sec/Div)

Please note that button functions are mode and state dependent. The following
chartslist button functions under various modes and states.

Basic Operations

1. Powering ON/OFF the Unit

2. Setting Parameters

1 ) If battery is connect ed and external power supply ( USB) is not used setting power switch to "BATT" position

will turn t he oscilloscope on. Settin g the switch to "USB" position will turn the unit off.

2 ) If USB is connected ALWAYS keep the power switch at "USB" position and use plugg ing/unplugging to

powe r on/off the uni t.

3 ) If you un-intentionally placed t he switch a t "BATT" position while USB is conn ected you may find the unit can

not be power on no matter by the switch or by plugging in USB cable . In th is case unplug USB cable and set the
switch to " USB" position. Wait for 10 - 30 seconds or longer the n turn it on by s witch or pluggi ng in USB cable.

[Not e: This situation won't happe n if the bulit-in battery charger was disconnected. For how to dis connect

battery charger please s ee explanation below]

1 ) Vert ical -

,

, and

Sensitivity Position

Coupling

Ø

Use the top two sli de switches to set sensitiv ity

Ø

Use [VPOS] and [ + ] [ - ] but tons to change waveform vertical position

Ø

Use the bottom slide switches to s elect coupling

2 ) Horizontal -

and

Timebase

Position

Ø

Use [ Sec/Div] and [ + ] [ - ] buttons to set timebase

Ø

Use [HPOS] and [ + ] [ - ] to change waveform horizontal po sition

3 ) Trigger -

,

, and

Mode Slope

Level

Ø

Use [M ODE] and [ + ] [ - ] buttons to select trigger mode

Ø

Use [SLOPE] and [ + ] [ - ] buttons to select trigger slope

Ø

Use [LEVEL] an d [ + ] [ - ] buttons to change tr igger level