JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS23x, 34x, 43x
37
“CN2” - RS485 IN/OUT. M12 - 5pin female connector.
Signal name
Description
Pin no.
JVL Cable
WI1000-M12
M5T
xx
N
Isolation
group
(See note)
RS485: B+
RS485 interface. Leave open if unused
1
Brown
1
RS485: A-
RS485 interface. Leave open if unused
2
White
1
RS485: B+
RS485 interface. Leave open if unused
3
Blue
1
RS485: A-
RS485 interface. Leave open if unused
4
Black
1
GND
Ground intended to be used toghether with the
other signals in this connector
5
Grey
1
“CN3” - RS485 + I/O connector - M12 - 8pin female connector.
Signal name
Description
Pin no.
JVL Cable
WI1000-M12
M8T
xx
N
Isolation
group
(See note)
IO1
I/O channel 1. Can be used as input or output
1
White
1
IO2
I/O channel 2. Can be used as input or output
2
Brown
1
IO3
I/O channel 3. Can be used as input or output
3
Green
1
GND
Ground intended to be used toghether with the
other signals in this connector
4
Yellow
1
RS485: B+
RS485 interface. Leave open if unused
5
Grey
1
RS485: A-
RS485 interface. Leave open if unused
6
Pink
1
IO4
I/O channel 4. Can be used as input or output
7
Blue
1
CVO
Supply output. Connected internally to the
CVI
terminal in the PWR connector.
DO NOT connect >30V to this terminal !
USB interface. Supply input 5VDC nominal
8
Red
1
“CN4” - RS485 + I/O + Backup
(option)
connector - M12 - 17pin female connector
Signal name
Description
Pin no.
JVL Cable
WI1009M12
M17T
xx
N
Isolation
group
(see note)
IO1
I/O channel 1. Can be used as input or output
1
Brown
1
GND
Ground intended to be used toghether with the other
signals in this connector
2
Blue
1
IO2
I/O channel 2. Can be used as input or output
3
White
1
IO3
I/O channel 3. Can be used as input or output
4
Green
1
B1-
RS422 I/O terminal B-
5
Pink
1
IO4
I/O channel 4. Can be used as input or output
6
Yellow
1
A1-
RS422 I/O terminal A-
7
Black
1
B1+
RS422 I/O terminal B+
8
Grey
1
CVO
Supply output. Connected internally to the
CVI
termi-
nal in the PWR connector.
DO NOT connect >30V to this terminal !
9
Red
1
A1+
RS422 I/O terminal A+
10
Violet
1
IO5
I/O channel 5. Can be used as input or output
11
Grey/pink
1
IO6
I/O channel 6. Can be used as input or output
12
Red/blue
1
IO7
I/O channel 7. Can be used as input or output
13
White/Green
1
IO8
I/O channel 8. Can be used as input or output
14
Brown/Green
1
RS485: B+
RS485 interface. Leave open if unused
15
White/Yellow
1
GND/
EXTBACKUP
Only for motors installed with the H3 option (absolute
multiturn encoder). This terminal can be connected to
an external supply.
Connect to ground if not used.
16
Yellow/brown
1
RS485: A-
RS485 interface. Leave open if unused
17
White/grey
1
* Note: Isolation group indicate which terminals/circuits that a galvanic connected to each other. In other
words group 1, 2, 3 and 4 are all fully independantly isolated from each other. Group 1 correspond to the
housing of the motor which may also be connected to earth via the DC or AC input supply.
Only MIS34x
Summary of Contents for MIS23 Series
Page 6: ...6 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 29: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 27 ...
Page 56: ...54 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 116: ...114 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 188: ...186 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 260: ...258 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 335: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 333 ...
Page 341: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 339 ...