JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS23x, 34x, 43x
107
Example 1:
Encoder (quadrature) input.
An external encoder feeds the MIS. The I/O type is set to “Pulse in-
put“ and “Input type” is set to “Quadrature” in order to decode the
encoder signal. The encoder is connected to the 2 pulse input termi-
nals. See also
How to connect the pulse source.
The resolution of the external encoder is 500 ppr. The MIS motor it-
self has 1600cpr (MIS23x) or 409600 cpr (MIS34x and MIS43x). If this
application requires that the MIS motor rotates 1 rev. each time the
external encoder has rotated 1 rev., the
Input
parameter is set to 500
(external encoder) and the
Output
parameter is set to 1600
(MIS23x)or 409600 (MIS34x or MIS43x).
Now the ratio between the external encoder and the MIS motor will
be 1:1. Ensure the “Profile data” is set to proper values in order not
to limit motor operation unintentionally.
Example 2:
Pulse and direction input.
A traditional step motor system with separate driver and motor is re-
placed by the integrated MIS motor, meaning that the MIS motor re-
ceives a pulse and direction signal which is a very common signal
format in step motor applications.
The I/O type is set to “Pulse input“ and “Input type” is set to “Pulse-
direction” in order to decode the input signal. The pulse signal is con-
nected to the 2 pulse input terminals. See also
The MAC motor is replacing a step motor system with 400 steps per
revolution, which means that when the pulse source produce 400
pulses, it expects the MIS motor to rotate one revolution.
The MIS motor itself has 1600cpr (MIS23x) or 409600 cpr (MIS34x
and MIS43x). If this application requires that the MIS motor rotates 1
revolution each time 400 pulses are received, the
Input
parameter is
set to 400 since the MIS motor interpret every rising edge at the ap-
plied pulse signal as one count (step).
The
Output
parameter is set to 1600 (MIS23x) or 409600 (MIS34x or
43x) since this is the number of counts (steps) on one revolution.
Now the MIS motor will move 1 revolution for every 400 pulses that
are applied to the pulse input. Ensure the “Profile data” is set to prop-
per values in order not to limit motor operation unintentionally.
The following table can be used as guide for setting up typical gear ra
tios:
Pulse and direction gear ratio setup - “Commonly used ratios”
Applied number of pulses(clocks)
per desired MIS motor revolution.
“Input”
register
“Output”
register
MIS23x
MIS34x or 43x
200
200
1600
409600
400
400
1600
409600
500
500
1600
409600
800
800
1600
409600
1000
1000
1600
409600
1600 (Equal to the MIS23x resolution)
1600
1600
409600
2000
2000
1600
409600
409600
(Equal to the MIS34x/43x resolution)
409600
1600
409600
Summary of Contents for MIS23 Series
Page 6: ...6 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 29: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 27 ...
Page 56: ...54 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 116: ...114 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 188: ...186 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 260: ...258 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 335: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 333 ...
Page 341: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 339 ...