JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
31
2.4
User Outputs
2.4.1
User outputs
The MIS motors has 8 inputs/outputs (IO’s) that each can be set individually to input, out-
put or analogue input 0-5V via MacTalk or software commands.This means that it for ex-
ample is possible to have 4 inputs, 3 outputs and one analogue input.
Please notice:
The number of available I/O terminals available may differ de-
pending at which motor type and connector configuration you are using. Please
Connector overview for the MIS motors
Input/output functional diagram
(only one I/O shown)
•
The Outputs are Source outputs and 7-28VDC compliant
• No galvanic isolation
• Short-circuit to ground protected that shuts down all outputs and sets Error bit in
software.
• Optional
“In Position”
and
“Error”
signals can be selected to be on any outputs 1 to 8
• Optional Encoder outputs
• 350 mA output current per channel even with all channels fully loaded at the same
time.
• Internal ground clamp diodes to protect when inductive load is driven.
!
TT2423-02GB
Internal µ-Processor
Digital input
CVI
(only input)
CVO
(only output)
(max 700mA)
10kOhm
Power
MosFet
Transistor
100pF
GND
GND
GND
4k7
+5V
IO1 to IO8
(Only one I/O shown)
Over current and
temperature protection
Over voltage
protection
Polyfuse
750mA
Analog input
Digital output
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...