288
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
11.4.10
Beckhoff receive PDO setup
The table below shows default values of the COB-ID:
Receive PDO1
Receive PDO 2:
With this PDO it is possible to update the running current and operating mode.
Receive PDO 3:
This PDO can be used to issue a Motor command.
Receive PDO 4:
This PDO updates the outputs.
Tables shown above are default mapping. The mapping can however also be changed dy-
PDO
Sub-
index
Type
Description
Default
Access
type
1
1
Receive
COB-ID
0x00000200
r/w
1
Transmit
COB-ID
0x00000180
r/w
2
1
Receive
COB-ID
0x00000300
r/w
1
Transmit
COB-ID
0x00000280
r/w
3
1
Receive
COB-ID
0x00000400
r/w
1
Transmit
COB-ID
0x00000380
r/w
4
1
Receive
COB-ID
0x00000500
r/w
1
Transmit
COB-ID
0x00000480
r/w
Byte
0
1
2
3
4
5
6
7
Data
P_SOLL
V_SOLL
A_SOLL
Object
2012h, sub 3
2014h, sub 5
2014h, sub 6
Byte
0
1
2
3
4
5
6
7
Data
RUN_CURRENT
MODE_REG
Available
Object
2014h, sub 7
2014h, sub 2
Byte
0
1
2
3
4
5
6
7
Data
Motor Command
Available
Object
2014h, sub 24
Byte
0
1
2
3
4
5
6
7
Data
Output data
Available
Object
2014h, sub 19
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...